Ion-Selective Electrode for Anionic Surfactants Using Hexadecyl Trimethyl Ammonium Bromide-Sodium Dodecylsulfate as an Active Ionophore

Abstract: The construction and characteristic performance of PVC membrane electrode responsive to sodium dodecylsulfate (SDS) are described in this paper. The electrode is based on hexadecyl trimethyl ammonium bromide-Sodium dodecylsulfate (CTA DS ) ion pair as ionophore in PVC membrane, which displays a Nernstian slope of 58 0.9 mV/decade in a 5.0 10 6 to 2.5 10 3 mol L 1 concentration range and a limit of detection of 2.9 10 6 mol L 1 . The electrode can be used for 3 months without showing significant changes in the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 24 publications
(27 reference statements)
0
2
0
Order By: Relevance
“…The dodecyl sulfate (DS − ) ion-selective electrode was fabricated using two commercially available Orion 900200 Sure-Flow Reference Half-Cell Ag/AgCl double junction electrodes and implemented with an Orion Star A329 potentiometer, as described in Supporting Information, Section I. Selectivity for DS − ion was based on a membrane prepared by adapting the procedure suggested by Wang and co-workers. 58 The electrode setup was used to obtain the concentration of free, uncomplexed DS − in solutions containing 10 000 ppm P123. All electrode measurements were conducted at 22 ± 2 °C.…”
Section: ■ Methodsmentioning
confidence: 99%
“…The dodecyl sulfate (DS − ) ion-selective electrode was fabricated using two commercially available Orion 900200 Sure-Flow Reference Half-Cell Ag/AgCl double junction electrodes and implemented with an Orion Star A329 potentiometer, as described in Supporting Information, Section I. Selectivity for DS − ion was based on a membrane prepared by adapting the procedure suggested by Wang and co-workers. 58 The electrode setup was used to obtain the concentration of free, uncomplexed DS − in solutions containing 10 000 ppm P123. All electrode measurements were conducted at 22 ± 2 °C.…”
Section: ■ Methodsmentioning
confidence: 99%
“…An amperometric sensor has been fabricated which employed surfactant-degrading microorganisms [7]. Several potentiometric sensors had been developed employing ionselective PVC membranes [8][9][10][11] and conducting polymers [12,13].…”
Section: Introductionmentioning
confidence: 99%