Ion Control for Optimized Imaging with a Novel Gaseous Detector

Abstract: A novel detector has been developed for imaging of insulating samples at very high magnification. The detector incorporates a dedicated electrode for the control of the ion flow to ensure correct charge control with any type of sample.It is well known that the gas ions in the gaseous detector are used to stabilize electron charging in environmental and variable pressure SEMs during the imaging of insulating samples with higher electron beam voltages. However, the gaseous detector can generate many more ions th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 1 publication
0
2
0
Order By: Relevance
“…Ways to quantify the efficiency of the pressure limiting system and to quantify the image quality have been presented earlier by Fitzek et al (2015). Inefficiencies in the design of the pressure limiting system and better designs for high-pressure SE detectors have been pointed out in several publications (Danilatos et al, 2001;Knowles et al, 2005;Toth et al, 2007;Danilatos, 2009;Danilatos et al, 2011;Dracopoulos & Danilatos, 2013). In this work a new design for the pressure limiting system is presented, which takes these insights into account.…”
Section: Introductionmentioning
confidence: 94%
See 1 more Smart Citation
“…Ways to quantify the efficiency of the pressure limiting system and to quantify the image quality have been presented earlier by Fitzek et al (2015). Inefficiencies in the design of the pressure limiting system and better designs for high-pressure SE detectors have been pointed out in several publications (Danilatos et al, 2001;Knowles et al, 2005;Toth et al, 2007;Danilatos, 2009;Danilatos et al, 2011;Dracopoulos & Danilatos, 2013). In this work a new design for the pressure limiting system is presented, which takes these insights into account.…”
Section: Introductionmentioning
confidence: 94%
“…(). Inefficiencies in the design of the pressure limiting system and better designs for high‐pressure SE detectors have been pointed out in several publications (Danilatos et al ., ; Knowles et al ., ; Toth et al ., ; Danilatos, ; Danilatos et al ., ; Dracopoulos & Danilatos, ). In this work a new design for the pressure limiting system is presented, which takes these insights into account.…”
Section: Introductionmentioning
confidence: 99%