1989
DOI: 10.1016/s0021-9673(01)89676-x
|View full text |Cite
|
Sign up to set email alerts
|

Ion chromatography on methacrylate ion exchangers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

1992
1992
2016
2016

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 9 publications
0
3
0
Order By: Relevance
“…Although this requirement is very simple to achieve from the preparation point of view, it is rather difficult to synthesize these exchangers reproducibly since the standard methods used for the determination of ion exchange capacity such as titration or elemental analysis are no longer accurate in the range of very small degrees of functionalization. Use of GMA beads modified with sulfonic acid and quaternary ammonium functionalities allowed for very good separations of both anions and cations, respectively [117,118]. Figure 14 shows an example of the separation of alkali metal and ammonium cations.…”
Section: Ion Exchange Chromatographymentioning
confidence: 99%
“…Although this requirement is very simple to achieve from the preparation point of view, it is rather difficult to synthesize these exchangers reproducibly since the standard methods used for the determination of ion exchange capacity such as titration or elemental analysis are no longer accurate in the range of very small degrees of functionalization. Use of GMA beads modified with sulfonic acid and quaternary ammonium functionalities allowed for very good separations of both anions and cations, respectively [117,118]. Figure 14 shows an example of the separation of alkali metal and ammonium cations.…”
Section: Ion Exchange Chromatographymentioning
confidence: 99%
“…In the present paper, the applicability of organic polymer-based monoliths to capillary IC has been experimentally investigated. Organic polymer-based monolithic capillary columns were prepared by a two-step procedure consisting of polymerization and sulfonation of glycidyl methacrylate (GMA), , and the chromatographic performance was evaluated through the separation of a model mixture of common cations. In addition, some promising results of flow rate gradient separation and direct injection determination are presented.…”
mentioning
confidence: 99%
“…This can usually be achieved by adding amino acidic [!] or alcoholic [2] modifiers to the eluent. In this paper the effect of polyethylene glycol (PEG) as an eluent modifier in increasing the separation selectivity of these cations is evaluated.…”
Section: Introduction 7lmentioning