2010
DOI: 10.1021/ac101247d
|View full text |Cite
|
Sign up to set email alerts
|

Ion Beam Analysis and PD-MS As New Analytical Tools for Quality Control of Pharmaceuticals: Comparative Study from Fluphenazine in Solid Dosage Forms

Abstract: In order to evaluate the potential of accelerator based analytical techniques ((particle induced X-ray emission (PIXE), particle induced gamma-ray emission (PIGE), and particle desorption mass spectrometry (PD-MS)) for the analysis of commercial pharmaceutical products in their solid dosage form, the fluphenazine drug has been taken as a representative example. It is demonstrated that PIXE and PIGE are by far the best choice for quantification of the active ingredient (AI) (certification with 7% precision) fro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
6
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…119 Both PIXE and PIGE were shown to be excellent techniques for the quantitation of active ingredients containing heteroatoms in solid tablets. Nsouli and colleagues have evaluated these techniques for the analysis of commercially available pharmaceutical products, including fluphenazine (an anti-psychotic drug containing S and F atoms), in their solid form.…”
Section: Ion Beam Techniquesmentioning
confidence: 99%
See 1 more Smart Citation
“…119 Both PIXE and PIGE were shown to be excellent techniques for the quantitation of active ingredients containing heteroatoms in solid tablets. Nsouli and colleagues have evaluated these techniques for the analysis of commercially available pharmaceutical products, including fluphenazine (an anti-psychotic drug containing S and F atoms), in their solid form.…”
Section: Ion Beam Techniquesmentioning
confidence: 99%
“…Nsouli and colleagues have evaluated these techniques for the analysis of commercially available pharmaceutical products, including fluphenazine (an anti-psychotic drug containing S and F atoms), in their solid form. 119 Both PIXE and PIGE were shown to be excellent techniques for the quantitation of active ingredients containing heteroatoms in solid tablets. However, since not all active ingredients contain heteroatoms, the use of PD-MS was evaluated as a means of determining active ingredients in the presence of excipients in the tablets.…”
Section: Ion Beam Techniquesmentioning
confidence: 99%
“…For example, we investigated the combination of PS activators in systems such as UVA/MIL88-A/PS or solar/MIL88-A/PS and monitored the impact on SMX removal in terms of degradation rate and transformation products nature and persistence. This was possible upon using the time of flight secondary ion mass spectrometry (ToF SIMS) technique previously used for the characterization of materials of environmental and pharmaceutical interests [59][60][61][62][63] as well as the Time of Flight high…”
Section: Introductionmentioning
confidence: 99%
“…For example, we investigated the combination of PS activators in systems such as UVA/MIL88-A/PS or solar/MIL88-A/PS and monitored the impact on SMX removal in terms of the degradation rate and transformation product nature and persistence. This was possible upon using the time of ight secondary ion mass spectrometry (ToF SIMS) technique previously used for the characterization of materials of environmental and pharmaceutical interest [59][60][61][62][63] as well as the time of ght high resolution mass spectrometry (ToF HRMS) technique for the identication of transformation products. Moreover, we studied the effect of various factors such as salinity, carbonates, and phosphates on the performance of both systems UVA/MIL88-A/ PS/SMX and solar/MIL88-A/PS/SMX toward SMX degradation and the potential application of this system on real pharmaceutical industry effluents.…”
Section: Introductionmentioning
confidence: 99%
“…PIGE is sensitive technique for low Z elements (Z \ 17) especially for lithium and fluorine [10,11]. It finds applications in many fields including pharmaceuticals [11], glass [12], teeth [13,14], aerosols [15] and geological and environmental reference materials [16,17]. This makes it complementary to techniques like particle induced X-ray emission (PIXE), X-ray fluorescence (XRF) and neutron activation analysis (NAA).…”
Section: Introductionmentioning
confidence: 99%