2011
DOI: 10.1039/c1ja10172b
|View full text |Cite
|
Sign up to set email alerts
|

Iolite: Freeware for the visualisation and processing of mass spectrometric data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
1,253
0
8

Year Published

2014
2014
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 3,139 publications
(1,366 citation statements)
references
References 13 publications
2
1,253
0
8
Order By: Relevance
“…Laser ablation conditions were as follows: ablation time of 60 s; fluence Bo3 J cm À 2 , repetition rate of 5 Hz; standard delay of 30 s for sample washout and background measurements; beam size of 55 mm. Raw data were reduced using the Iolite software package 64 . Isobaric interferences of 176 Yb and 176 Lu on 176 Hf were assessed and corrected following the procedure described by Woodhead et al 65 Plesovice zircon standard 66 was analysed to correct for instrumental drift, whereas Temora-2 and 91500 zircon references 67 Table 8).…”
Section: Methodsmentioning
confidence: 99%
“…Laser ablation conditions were as follows: ablation time of 60 s; fluence Bo3 J cm À 2 , repetition rate of 5 Hz; standard delay of 30 s for sample washout and background measurements; beam size of 55 mm. Raw data were reduced using the Iolite software package 64 . Isobaric interferences of 176 Yb and 176 Lu on 176 Hf were assessed and corrected following the procedure described by Woodhead et al 65 Plesovice zircon standard 66 was analysed to correct for instrumental drift, whereas Temora-2 and 91500 zircon references 67 Table 8).…”
Section: Methodsmentioning
confidence: 99%
“…A total of 10 isotopes were determined ( 43 Ca, 44 Ca, 201 Hg, 202 Hg, 204 Pb, 206 Pb, 207 Pb, 208 Pb, 232 Th and 238 U). The dwell time on the Pb isotopes was 0.1 s with Ca isotopes measured for 0.03 s and Hg, U and Th measured for 0.0125 s. Laser induced U-Pb fractionation was accounted for during data reduction Paton et al, 2010;Paton et al, 2011). McClure Mountain syenite apatite (Thomson et al, 2012) was used as the primary standard as it has moderate but reasonably consistent U and Th contents (~23 ppm and 71 ppm; (Chew and Donelick, 2012) (Schoene and Bowring, 2006).…”
Section: U-pb Geochronologymentioning
confidence: 99%
“…For example, the mean 206 Pb/ 238 U age determined for Plešovice was 327 ± 10 Ma (2σ, n = 12, MSWD = 1.0), within uncertainty of the recommended value. The time-resolved mass spectra were reduced using the U/Pb Geochronology3 data reduction scheme in Iolite (Paton et al, 2011). No common lead corrections were deemed necessary due to low 204 Pb counts.…”
Section: U-pb Geochronologymentioning
confidence: 99%
See 2 more Smart Citations