“…Most of the more recent studies discuss no-history procedures. [1][2][3][4][5]9,10,12 The formula presented here also belongs in the second class. It has been in clinical use for approximately 2 1 / 2 years, with the first experiences published in German.…”
mentioning
confidence: 88%
“…In the past few years, increasing attention has been given to this problem. [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15] Three main sources of error have been identified. 16 First, curvature measurements are erroneous because they are not obtained from the corneal center (radius error).…”
mentioning
confidence: 99%
“…The proposed solutions to these problems can be divided into 2 classes: (1) procedures requiring patient historical data and (2) methods relying only on current measurements. An important member in the first class is the refractive history method, 17,18 which serves as a gold standard.…”
mentioning
confidence: 99%
“…It has been in clinical use for approximately 2 1 / 2 years, with the first experiences published in German. 1,2 It is also included in the operating software of the IOLMaster (version 4.0 and later, Carl Zeiss Meditec AG).…”
The new formula would produce promising results in eyes without refractive history. Its refractive predictability fulfills the current criteria for normal eyes.
“…Most of the more recent studies discuss no-history procedures. [1][2][3][4][5]9,10,12 The formula presented here also belongs in the second class. It has been in clinical use for approximately 2 1 / 2 years, with the first experiences published in German.…”
mentioning
confidence: 88%
“…In the past few years, increasing attention has been given to this problem. [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15] Three main sources of error have been identified. 16 First, curvature measurements are erroneous because they are not obtained from the corneal center (radius error).…”
mentioning
confidence: 99%
“…The proposed solutions to these problems can be divided into 2 classes: (1) procedures requiring patient historical data and (2) methods relying only on current measurements. An important member in the first class is the refractive history method, 17,18 which serves as a gold standard.…”
mentioning
confidence: 99%
“…It has been in clinical use for approximately 2 1 / 2 years, with the first experiences published in German. 1,2 It is also included in the operating software of the IOLMaster (version 4.0 and later, Carl Zeiss Meditec AG).…”
The new formula would produce promising results in eyes without refractive history. Its refractive predictability fulfills the current criteria for normal eyes.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.