2003
DOI: 10.1016/s0263-2241(02)00079-9
|View full text |Cite
|
Sign up to set email alerts
|

Investigations of van der Pauw method applied for measuring electrical conductivity of electrolyte solutions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 25 publications
(8 citation statements)
references
References 10 publications
0
7
0
1
Order By: Relevance
“…The obtained data at room temperature and atmospheric pressure were analyzed using equation (3), where the correction factor f has been neglected due to the symmetry of the measurement cell as discussed in the introduction. The validity of the applied method has been proven by Moroń [12]. The value for Z CA,DB was determined at the beginning of a measurement sequence, and the ratio Z CA,DB_STP /Z AB,CD_STP , which is assumed temperature independent, is used to calculate the conductivity over the entire temperature range without further electrode rotating, by making use of equation (4).…”
Section: Conductivity Measurement Setupmentioning
confidence: 99%
“…The obtained data at room temperature and atmospheric pressure were analyzed using equation (3), where the correction factor f has been neglected due to the symmetry of the measurement cell as discussed in the introduction. The validity of the applied method has been proven by Moroń [12]. The value for Z CA,DB was determined at the beginning of a measurement sequence, and the ratio Z CA,DB_STP /Z AB,CD_STP , which is assumed temperature independent, is used to calculate the conductivity over the entire temperature range without further electrode rotating, by making use of equation (4).…”
Section: Conductivity Measurement Setupmentioning
confidence: 99%
“…Although the designed probe has been suggested for internal body tissues, such as measuring the electrical properties of the lung tissue during the bronchoscopy procedure, it is useful to compare its efficiency with other methods such as the non‐invasive four electrode array [19] and van der Pauw [20]. The reason for choosing these two methods is that they have been used experimentally and approved by different researchers [21, 22]. In this comparison, we consider the living tissue as a cube‐shaped structure with dimensions 50 thinmathspacemm × 50 thinmathspacemm × 30 thinmathspacemm.…”
Section: Resultsmentioning
confidence: 99%
“…Moron showed that the van der Pauw's technique could measure the electrical resistivity of electrolyte solutions and applied this method to determine the electrical conductivity of a salt solution. [ 21 , 26 , 27 ].…”
Section: Introductionmentioning
confidence: 99%