2021
DOI: 10.37934/arfmts.79.2.4864
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on The Thermal Performance of Evacuated Glass-Thermal Absorber Tube Collector (EGATC) for Air Heating Application

Abstract: Existing design of Heat-Pipe Evacuated Tube Collector (HP ETC) for solar water heating require storage tank and additional heat exchanger required for air heating application which leads to the extra spacing and costing requirement. HP ETC have better thermal performance to produce high outlet temperature than flat plate collector (FPC), especially during diffuse solar radiation. But HP ETC normally focusing on water heating system. Furthermore, HP ETC and FPC installation need to be positioned either to south… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
1
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 24 publications
(29 reference statements)
0
1
0
Order By: Relevance
“…The wind speed was measured by UNI-T Mini Digital Anemometer (UT363). The solar thermal collector applied in this research namely Evacuated Glass-Thermal Absorber Tube Collector (EGATC) was reported in previous study by Zakaria et al, [32]. The thermal absorber was divided into two (2) parts particularly inner absorber and outer absorber.…”
Section: Methodology 21 Device and Apparatusmentioning
confidence: 99%
“…The wind speed was measured by UNI-T Mini Digital Anemometer (UT363). The solar thermal collector applied in this research namely Evacuated Glass-Thermal Absorber Tube Collector (EGATC) was reported in previous study by Zakaria et al, [32]. The thermal absorber was divided into two (2) parts particularly inner absorber and outer absorber.…”
Section: Methodology 21 Device and Apparatusmentioning
confidence: 99%
“…Recently, Zakaria et al [68] proposed an improved evacuated tube design known as the evacuated glass-thermal absorber tube collector (EGATC) that outperformed the heat pipe evacuated tube collector in terms of temperature differences and output temperature. The inner and outer absorbers are the two components that made up the thermal absorber.…”
Section: Number Of Passesmentioning
confidence: 99%
“…Both heat absorbers are incorporated inside the evacuated glass. With the system's double pass flow and preheating flow at the inner absorber, the revolutionary thermal absorber design produces a high cumulative temperature at the output temperature [69].…”
Section: Number Of Passesmentioning
confidence: 99%
“…Supankanok et al (2021) [11] improved heat transfer from the aluminum fin to the copper heat pipe by modifying the internal construction of the evacuated tube. Zakaria et al (2022) [12] studied the influence of various factors, such as air contact with the surface area of the internal absorber. Shi et al (2019) [13] performed an analysis of fin structure parameters (fin thickness and fin spacing) in an evacuated tube with phase change material.…”
Section: Introductionmentioning
confidence: 99%