“…The topographic evaluation of the surface state was made with the equipment "Stereoscan S360" from Cambridge Instruments, Great Britain, which was adapted with an EDXA system "Delta Analyzer" from Kevex, USA. The experimental parameters were analogous to these in [7]: acceleration voltage 25kV, Li drifted Si detector, residual gas pressure < 1.10-4pa, probe current <2hA. The experiments were carried out as a standard-less EDX analysis.…”
Section: Methodsmentioning
confidence: 99%
“…The topographic evaluation of the surface state was made with the equipment "Stereoscan S360" from Cambridge Instruments, Great Britain, which was adapted with an EDXA system "Delta Analyzer" from Kevex, USA. The experimental parameters were analogous to these in [7]: acceleration voltage 25kV, Li drifted Si detector, residual gas pressure < 1.10-4pa, probe current <2hA. The experiments were carried out as a standard-less EDX analysis.…”