2013 10th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technolo 2013
DOI: 10.1109/ecticon.2013.6559509
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on partial discharge of power cable termination defects using High Frequency Current Transformer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2016
2016
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 1 publication
0
8
0
Order By: Relevance
“…Lee et al [9] carried out a series of experiments to determine the resultant partial discharge behavior of defects inside cable insulation at a termination. Other researchers [10][11] have introduced AC voltage and investigated the resultant PD pattern in different kinds of cable termination defects. However, there is little research investigating the behavior of cable insulation with defects when exposed to a DC voltage combined with an AC harmonic voltage.…”
Section: Introductionmentioning
confidence: 99%
“…Lee et al [9] carried out a series of experiments to determine the resultant partial discharge behavior of defects inside cable insulation at a termination. Other researchers [10][11] have introduced AC voltage and investigated the resultant PD pattern in different kinds of cable termination defects. However, there is little research investigating the behavior of cable insulation with defects when exposed to a DC voltage combined with an AC harmonic voltage.…”
Section: Introductionmentioning
confidence: 99%
“…Many studies have reported that corona discharges are indirectly generated from the cable or its termination but may originate from the switchgear and cable/terminal hardware connection [9]. Many researchers [20], [22]- [24] used a needle or electrode as a sharp point in their experiments to analyse the characteristics of corona discharges in XLPE cables. The shape of the electrodes under HV stress enormously influences the corona discharge characteristics at low inception voltage.…”
Section: Figure 5 Example Of Measurement Results Of Corona Discharge Display On Sinusoidalmentioning
confidence: 99%
“…A long‐distance cable line is mainly composed of the main body of the cable, terminals, insulating joints (IJ), and normal joints (NJ). PD measurement is often performed at the terminal, as the access is relatively easy . Katsuta et al proposed a method to detect PD at the IJ where the metallic shield is electrically discontinued.…”
Section: Introductionmentioning
confidence: 99%
“…PD measurement is often performed at the terminal, a Correspondence to: Naohiro Hozumi. E-mail: hozumi@ee.tut.ac.jp Toyohashi University of Technology, Department of Electrical and Electronic Information Engineering, 1-1 Hibarigaoka, Tempaku Toyohashi, Aichi, 441-8580, Japan as the access is relatively easy [18][19][20][21][22]. Katsuta et al proposed a method to detect PD at the IJ where the metallic shield is electrically discontinued.…”
Section: Introductionmentioning
confidence: 99%