2019 IEEE International Conference on Industrial Technology (ICIT) 2019
DOI: 10.1109/icit.2019.8755017
|View full text |Cite
|
Sign up to set email alerts
|

Investigation on an AC Grid Failure Handling of Industrial DC Microgrids with an Energy Storage

Abstract: A new approach for more energy efficient industrial production processes are smart industrial direct current (DC) microgrids with one or more connections to the alternative current (AC) grid. The advantage of the DC-technology is an easier integration of renewable energies sources and energy storage systems (ESS). Different applications for ESS are possible, for instance an uninterruptible power supply (UPS) for a DC microgrid. Within this paper, a new handling concept for a mains supply failure (e.g. a blacko… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
10
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(10 citation statements)
references
References 14 publications
(21 reference statements)
0
10
0
Order By: Relevance
“…For model validation, a DC microgrid test rig (Fig. 7) was set up which has already been used in [29]- [32]. The test rig contains mains supply (sup) with adaptive droop curve control which is the main supplier to the DC microgrid.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…For model validation, a DC microgrid test rig (Fig. 7) was set up which has already been used in [29]- [32]. The test rig contains mains supply (sup) with adaptive droop curve control which is the main supplier to the DC microgrid.…”
Section: Methodsmentioning
confidence: 99%
“…In this work the DC microgrid model, based on [29] and [30], is simplified to an electric network with one capacity C DC between the DC terminals. If we neglect the transmission line impedances, the sum of the participants' currents i n of the DC microgrid are equal to zero.…”
Section: System Modeling and Simulation A Dc-grid Modelingmentioning
confidence: 99%
“…The model was validated in [1] with the test setup described in [11]. The error between simulated and measured rectifier power for a 15 minute measurement is less than 4.5 %.…”
Section: A DC Grid Modelingmentioning
confidence: 99%
“…5 results. Optically the characteristics differ the droop curves, which were created according to [11], conventionally generated voltage droop curves. due to the decreasing of the gradient at ± 80 %, as well as the smaller plateaus in the battery curve.…”
Section: B Voltage Droop Curves With Fuzzy Logicmentioning
confidence: 99%
See 1 more Smart Citation