2016
DOI: 10.1016/j.electacta.2016.09.013
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Voltammetric Behaviour of Insecticide Chlorpyrifos on a Mercury Meniscus Modified Silver Solid Amalgam Electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(10 citation statements)
references
References 47 publications
0
10
0
Order By: Relevance
“…Although mercury electrodes show lower LODs for the quantitative determination of CPF, the use of mercury may cause environmental problems. In addition, the determination studies performed at RGO/GCE appear to have a lower LOD value compared to those carried out by Sreedar et al, 2015, Kumaravel et al, 2015and Fischer et al J., 2016 Repeatability and Selectivity Repeatability and reproducibility of the proposed sensor were confirmed by taking DPAdSV measurements of 6.03x10 -8 M CPF in 0.1M NaOH at various times using modified electrodes. The RSD value of the peak currents showing the repeatability was 0.069 % with the data obtained at different times using the same electrode.…”
Section: Determination Of Cpf By Dpadsvmentioning
confidence: 57%
See 1 more Smart Citation
“…Although mercury electrodes show lower LODs for the quantitative determination of CPF, the use of mercury may cause environmental problems. In addition, the determination studies performed at RGO/GCE appear to have a lower LOD value compared to those carried out by Sreedar et al, 2015, Kumaravel et al, 2015and Fischer et al J., 2016 Repeatability and Selectivity Repeatability and reproducibility of the proposed sensor were confirmed by taking DPAdSV measurements of 6.03x10 -8 M CPF in 0.1M NaOH at various times using modified electrodes. The RSD value of the peak currents showing the repeatability was 0.069 % with the data obtained at different times using the same electrode.…”
Section: Determination Of Cpf By Dpadsvmentioning
confidence: 57%
“…Therefore, a simpler, faster and, cost-efficient method is required to detect CPF (Huang et al, 2020). Electrochemical methods were employed for simple, fast and cost-efficient determination of CPF (Al-Meqbali et al, 1998;Manisankar et al, 2005;Pelit et al, 2011;Kumaravel et al, 2015;Sreedar et al,2015;Fischer et al J.,2016;Melo et al,2018;Joshi et al, 2020) Being one of the most prominent elements of the periodic table, carbon has a total of five allotropes including fullerene, carbon nanotube, graphene, graphite, and diamond. While diamond and graphite which have been known since ancient times are three-dimensional allotropes, nanotube discovered in the 90s is one-dimensional and fullerene is zero-dimensional.…”
Section: Introductionmentioning
confidence: 99%
“…They can be used in analysis of inorganic [14,16,17] as well as 8 organic [18][19][20][21][22] compounds or biomolecules as proteins [23][24][25] and DNA 9 [26][27][28][29]. Many papers have also been focused on determining of various 10 pesticides using amalgam electrodes [30][31][32][33][34][35]. 11…”
Section: Fig 1 Structural Formula Of Azoxystrobinmentioning
confidence: 99%
“…The increase in the use of pesticides often results in many adverse impacts, especially on the agricultural environment [6, 7]. For this reason, various analytical techniques are used to test pesticides, including chromatographic methods [8, 9].…”
Section: Introductionmentioning
confidence: 99%