2012
DOI: 10.1007/s00330-012-2675-z
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of viewing procedures for interpretation of breast tomosynthesis image volumes: a detection-task study with eye tracking

Abstract: ObjectivesTo evaluate the efficiency of different methods of reading breast tomosynthesis (BT) image volumes.MethodsAll viewing procedures consisted of free scroll volume browsing and three were combined with initial cine loops at three different frame rates (9, 14 and 25 fps). The presentation modes consisted of vertically and horizontally orientated BT image volumes. Fifty-five normal BT image volumes in mediolateral oblique view were collected. In these, simulated lesions were inserted, creating four unique… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
12
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(13 citation statements)
references
References 44 publications
1
12
0
Order By: Relevance
“…[28][29][30] Improved lesion visibility, size and classification compared with standard film or digital mammography have been reported [31][32][33][34][35][36][37][38] and the possibility that DBT could reduce the need for additional mammographic views at least for non-calcified lesions [39][40][41][42] has been suggested. There are mixed reports of the sensitivity of DBT for the detection of microcalcifications 32,[43][44][45][46][47][48][49][50][51] that may be partly as a result of the different techniques used for image reconstruction and the need to combine image slices into thicker slabs for optimal visualisation of microcalcification clusters. These observations suggested that DBT was unlikely to be used as a stand-alone imaging modality if a 2D mammogram was required for optimal microcalcification assessment.…”
Section: Diagnostic Accuracymentioning
confidence: 99%
See 1 more Smart Citation
“…[28][29][30] Improved lesion visibility, size and classification compared with standard film or digital mammography have been reported [31][32][33][34][35][36][37][38] and the possibility that DBT could reduce the need for additional mammographic views at least for non-calcified lesions [39][40][41][42] has been suggested. There are mixed reports of the sensitivity of DBT for the detection of microcalcifications 32,[43][44][45][46][47][48][49][50][51] that may be partly as a result of the different techniques used for image reconstruction and the need to combine image slices into thicker slabs for optimal visualisation of microcalcification clusters. These observations suggested that DBT was unlikely to be used as a stand-alone imaging modality if a 2D mammogram was required for optimal microcalcification assessment.…”
Section: Diagnostic Accuracymentioning
confidence: 99%
“…Since there is some uncertainty over the visibility of microcalcification clusters, 17,43,44,48,49,51 it has been suggested that a standard 2D mammogram may be required along with two-view DBT for optimal microcalcification assessment. 16,25,47,53,88 However, concerns have been raised regarding the additional radiation dose this would involve.…”
Section: Reading Armsmentioning
confidence: 99%
“…The studies that dealt with volumetric imaging material [45][46][47][48][49][50][51][52][53][54][55][56][57][58][59][60][61] used images suitable for a three-dimensional representation of the human body, however, the presentation of stimulus material differed between them. Eight of the studies presented all slices of a multislice case and allowed radiologists to scroll freely through these stacks; 49,52,[55][56][57][58][59][60] thus, radiologists could scroll back and forth for as long as they wanted to and also determine the pace of their movement through the stack.…”
Section: Stimulus Materialsmentioning
confidence: 99%
“…Eight of the studies presented all slices of a multislice case and allowed radiologists to scroll freely through these stacks; 49,52,[55][56][57][58][59][60] thus, radiologists could scroll back and forth for as long as they wanted to and also determine the pace of their movement through the stack. In two experiments, the radiologists were presented with five consecutive slices of MRI and CT cases, but they were only able to scroll in the forward direction, meaning that once they had chosen to scroll on, they were not able to return to a previous slice.…”
Section: Stimulus Materialsmentioning
confidence: 99%
See 1 more Smart Citation