Investigation of time, amplitude, and frequency parameters of a direct fetal ECG signal during labor and delivery

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…In the simulation, the strength of the FECG, the MECG and the noise were adjusted such that SNR = SIR + 10dB, and SINR was swept in the range of -35dB to -15dB. Note that in the experiment the SINR range was intentionally made more challenging, since for most raw recordings the SINR varies only from -5dB to -25dB [37]. For each value of the SINR, the simulation was repeated 20 times, each time with different signals and noise.…”
Section: A Effects Of Signal-to-interference-and-noise Ratiomentioning
confidence: 99%
“…In the simulation, the strength of the FECG, the MECG and the noise were adjusted such that SNR = SIR + 10dB, and SINR was swept in the range of -35dB to -15dB. Note that in the experiment the SINR range was intentionally made more challenging, since for most raw recordings the SINR varies only from -5dB to -25dB [37]. For each value of the SINR, the simulation was repeated 20 times, each time with different signals and noise.…”
Section: A Effects Of Signal-to-interference-and-noise Ratiomentioning
confidence: 99%
“…The challenge is to extract the FECG from the composite signal, considering that the two signals are superimposed spectrally, and that the fetal QRS complex amplitude may be less than 3% from the maternal QRS complex [2].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, this measure is a suitable candidate for the stopping criterion , in the deflation algorithm. The definition of PM may also be extended to vectorial data (23) which can be used as an overall measure of periodicity for multichannel data. Note that the reduction of or is a necessary, but not a sufficient measure of the filtering performance.…”
Section: B Real Data 1) Evaluation Measuresmentioning
confidence: 99%
“…Fetal ECG (fECG) recorded from the maternal abdomen are heavily contaminated with maternal ECG (mECG), which depending on the gestational age and electrode locations, can be up to twenty times stronger than the fetal components [22], [23]. Independent subspace analysis (ISA) and other ICA-based methods are the most common approaches for fECG extraction.…”
Section: Application In Fetal Ecg Extractionmentioning
confidence: 99%