2023
DOI: 10.3390/molecules28041940
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Thermodynamic Properties of Dimethyl Phosphate-Based ILs for Use as Working Fluids in Absorption Refrigeration Technology

Abstract: In the current research, the binary solution containing ionic liquid (IL), 1-ethyl-1-methylmorpholinium dimethyl phosphate ([C1C2MOR][DMP]), 1-ethyl-1-methylpiperidinium dimethyl phosphate ([C1C2PIP][DMP]), or N,N,N-triethyl-N-methylammonium dimethyl phosphate ([N1,2,2,2][DMP]) with ethanol are investigated as new working fluids for absorption refrigeration technology. The IL was mixed with ethanol, which was considered as a refrigerant. Experimental (vapor + liquid) phase equilibria (VLE) of these binary syst… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(15 citation statements)
references
References 55 publications
0
15
0
Order By: Relevance
“…Figure 5 shows that the ethanolic system with the ammonium-based ionic liquid shows the lowest density. These data, supplemented by the promising vapor pressure values presented earlier, 23 Temperature dependence of the dynamic viscosity for the binary systems under study was described using the following Andrade-type equation…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Figure 5 shows that the ethanolic system with the ammonium-based ionic liquid shows the lowest density. These data, supplemented by the promising vapor pressure values presented earlier, 23 Temperature dependence of the dynamic viscosity for the binary systems under study was described using the following Andrade-type equation…”
Section: Resultsmentioning
confidence: 99%
“…It ought to be noted that all ionic liquids except [C 1 Py]­[DMP] exhibited a glass transition temperature and heat capacity at the glass transition temperature. The following series shows how these numbers rise: [C 1 C 2 PYR]­[DMP] ( T g = 189.7 K, Δ g C p = 119.6 J mol –1 K –1 ) < [N 1,2,2,2 ]­[DMP] ( T g = 194.4 K, Δ g C p = 154.4 J mol –1 K –1 ) ∼ [C 1 C 2OH PYR]­[DMP] ( T g = 194.9 K, Δ g C p = 148.1 J mol –1 K –1 ) < [C 1 C 2 IM]­[DMP] (this work) ( T g = 203.8 K, Δ g C p = 144.1 J mol –1 K –1 ) < [C 1 C 1 IM]­[DMP] (this work) ( T g = 207.4 K, Δ g C p = 128.9 J mol –1 K –1 ) < [C 1 C 2 PIP]­[DMP] ( T g = 211.0 K, Δ g C p = 103.9 J mol –1 K –1 ) < [C 1 C 2 MOR]­[DMP] ( T g = 222.2 K, Δ g C p = 132.7 J mol –1 K –1 ). Only a glass transition occurred for the ionic liquids [C 1 C 1 IM] [DMP], [C 1 C 2 MOR]­[DMP], and [C 1 C 2OH PYR]­[DMP] in the temperature range investigated.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations