2022
DOI: 10.3390/s22114195
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Possibility of Using Microspectrometers Based on CMOS Photodiode Arrays in Small-Sized Devices for Optical Diagnostics

Abstract: The article considers the potential applicability of C12880MA and C11708MA Hamamatsu microspectrometers, which are characterized by an extremely compact design, occupying a small volume of several cubic centimeters, in portable spectrometric equipment with spatial resolution for monitoring the optical properties of condensed scattering media. The development of methods for determining the reduced scattering and absorption spectral coefficients of radiation from various scattering materials and products allows … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 28 publications
0
2
0
Order By: Relevance
“…In the short-wavelength part of the spectral dependencies for the second and fourth samples, the influence of parasitic radiation is manifested, which is scattered by the concave diffraction grating of the spectrometer into the zero order of diffraction. This effect was revealed by us earlier when calibrating AvaSpec 2048WL and C12880MA Hamamatsu spectrometers according to reference emitters with different temperatures [37,40,41]. The halo maximum of weak radiation scattered by the concave diffraction grating of the AvaSpec 2048WL spectrometer to zero order is located in the area that corresponds to diffracted blue radiation.…”
Section: Results Of Experimental Investigationmentioning
confidence: 75%
See 1 more Smart Citation
“…In the short-wavelength part of the spectral dependencies for the second and fourth samples, the influence of parasitic radiation is manifested, which is scattered by the concave diffraction grating of the spectrometer into the zero order of diffraction. This effect was revealed by us earlier when calibrating AvaSpec 2048WL and C12880MA Hamamatsu spectrometers according to reference emitters with different temperatures [37,40,41]. The halo maximum of weak radiation scattered by the concave diffraction grating of the AvaSpec 2048WL spectrometer to zero order is located in the area that corresponds to diffracted blue radiation.…”
Section: Results Of Experimental Investigationmentioning
confidence: 75%
“…The spectral resolution of modern portable spectrometers based on concave diffraction gratings and linear CCD arrays is sufficient for the problem under consideration [36,40,41], since the absorption spectra of condensed media are smooth, in contrast to the spectra of gases. The presence of instability of the parameters of the equipment used, radiation noise, and intrinsic noise of the spectrometer linear CCD array, as well as the deterioration of the signal-to-noise ratio of the recorded spectra at the edges of the spectral range used, limits the possibilities of the proposed method.…”
Section: Methods Of Measurement and Processing Of Spectral Dependenciesmentioning
confidence: 99%