2018
DOI: 10.12737/article_5a82eb9a9bbac1.67972336
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Influence of the Conditioning Medium Factors Obtained During the Cultivation of Bone Marrow Mesenchymal Stem Cells on the Course of Severe Local Radiation Injuries of Skin in Rats

Abstract: Purpose: Study of the effect of paracrine factors, produced by MMSC of bone marrow during the cultivation, on the severity of local radiation injuries in the conditions of application in the early periods after irradiation. Material and methods: Experiments were performed on rats of the breed Wistar weighing 280 g. Rats were exposed locally in iliolumbar region of the back using X-ray machine LNC-268 (RAP 100-10) at a dose of 110 Gy (30 kV tube voltage, current 6.1 mA, filter Al 0.1 mm thick), dose rate is 21.… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 1 publication
0
1
0
Order By: Relevance
“…Modeling of relatively "soft" X-ray radiation of LRI was carried out on an LNK-268 (RAP100-10) X-ray unit (Diagnostika-M LLC, Moscow, Russia) with a radiation exposure mode at a dose of 110 Gy with a 0.1 mm aluminum filter, voltage 30 kV, beam current 6.1 mA, dose rate 21.1 Gy/min for 312 s (dose accuracy ± 5%, dose measurement uncertainty ± 6%) according to the proposed earlier method [10][11][12], leading to a short latency period and chronic skin ulcer in laboratory animals. After irradiation, the animals were seated in individual sterile boxes with an autonomous Smart Flow ventilation system (Tecniplast Group, Buguggiate, Italy), with free access to water and food.…”
Section: Modeling Of Lrimentioning
confidence: 99%
“…Modeling of relatively "soft" X-ray radiation of LRI was carried out on an LNK-268 (RAP100-10) X-ray unit (Diagnostika-M LLC, Moscow, Russia) with a radiation exposure mode at a dose of 110 Gy with a 0.1 mm aluminum filter, voltage 30 kV, beam current 6.1 mA, dose rate 21.1 Gy/min for 312 s (dose accuracy ± 5%, dose measurement uncertainty ± 6%) according to the proposed earlier method [10][11][12], leading to a short latency period and chronic skin ulcer in laboratory animals. After irradiation, the animals were seated in individual sterile boxes with an autonomous Smart Flow ventilation system (Tecniplast Group, Buguggiate, Italy), with free access to water and food.…”
Section: Modeling Of Lrimentioning
confidence: 99%