2020
DOI: 10.1109/cjece.2019.2914959
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the Effects of Stator Slot Permeance on Induction Motor and Obtaining the Best Starting Torque Using Permeance Calculation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 10 publications
(4 citation statements)
references
References 14 publications
0
4
0
Order By: Relevance
“…Total leakage reactance is sum of slot, overhang, zigzag, and differential leakage reactance. 21,24 Theory states that the slot leakage reactance is inversely proportional to the number of slots per pole per phase. In this study, only slot leakage reactance is considered.…”
Section: Leakage Reactancementioning
confidence: 99%
See 1 more Smart Citation
“…Total leakage reactance is sum of slot, overhang, zigzag, and differential leakage reactance. 21,24 Theory states that the slot leakage reactance is inversely proportional to the number of slots per pole per phase. In this study, only slot leakage reactance is considered.…”
Section: Leakage Reactancementioning
confidence: 99%
“…But it broadly depends on factors like conductors per slot, number of pole ( p), slot per pole per phase, and turns per phase ( Tph). Total leakage reactance is sum of slot, overhang, zig‐zag, and differential leakage reactance 21,24 . Theory states that the slot leakage reactance is inversely proportional to the number of slots per pole per phase.…”
Section: Influence Of Slot Per Pole Per Phasementioning
confidence: 99%
“…Stermecki A. and Lee G. et al. discussed the method of improving starting torque from EM structure of the motor by carrying out detailed studies on the optimal design of stator winding, rotor slot shape, and the shape of rotor bar [15–19]. Badr M. A. et al.…”
Section: Introductionmentioning
confidence: 99%
“…[10][11][12][13][14]. Stermecki A. and Lee G. et al discussed the method of improving starting torque from EM structure of the motor by carrying out detailed studies on the optimal design of stator winding, rotor slot shape, and the shape of rotor bar [15][16][17][18][19]. Badr M. A. et al proposed to start the motor in a single phase mode with the help of a properly selected phase balancer capacitor [20]; Hu W. T. and his colleagues proposed to impose a certain direction stator voltage vector to make the flux reach stability faster [21], and then both of them realised starting process by switching to AC operation.…”
Section: Introductionmentioning
confidence: 99%