2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2014
DOI: 10.1109/embc.2014.6943998
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Pulse Transit Times utilizing multisite reflectance photoplethysmography under conditions of artificially induced peripheral vasoconstriction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
18
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(18 citation statements)
references
References 8 publications
0
18
0
Order By: Relevance
“…The monitoring was continued until the volunteer's hand rewarmed to a minimum temperature above 24°C. The minimum and maximum time it took the volunteers to rewarm their hand to 24°C was 7 min 9 s and 12 min 30 s. More information regarding the protocol is presented in Budidha and Kyriacou (2014a,b).…”
Section: Methodsmentioning
confidence: 99%
“…The monitoring was continued until the volunteer's hand rewarmed to a minimum temperature above 24°C. The minimum and maximum time it took the volunteers to rewarm their hand to 24°C was 7 min 9 s and 12 min 30 s. More information regarding the protocol is presented in Budidha and Kyriacou (2014a,b).…”
Section: Methodsmentioning
confidence: 99%
“…5 PPG has found its utility in a vast number of applications, such as neonatal care, hemorheology assessment, pulse transit time investigation, and measurements from body cavities and organs. [6][7][8][9][10][11][12] Near-infrared spectroscopy (NIRS) is another noninvasive optical technique, which measures variations in local blood perfusion by estimating changes in oxy-hemoglobin, deoxyhemoglobin, and total hemoglobin. 13 These physiological variables are determined using the Beer-Lambert law, correlating the attenuation of light A, through a medium with the concentration C of the absorber (chromophore) present in the solution.…”
Section: Introductionmentioning
confidence: 99%
“…12 shows the calculated R-values from both the ZenPPG channels against the simulated SpO 2 values. A second-degree polynomial was used to derive the following calibration functions from the R-values: Using these calibration curves, the functionality and accuracy of both the ZenPPG channels as pulse oximeters was tested on eight healthy volunteers (aged [21][22][23][24][25][26][27][28][29][30][31][32]. In this brief study, PPG signals were recorded from index and the middle fingers (right hand) of the volunteers using two Masimo reusable sensors (Masimo Inc., California, USA) connected to the ZenPPG system for 2 min.…”
Section: B Preliminary Evaluationmentioning
confidence: 99%
“…Another example of the system's flexibility is the newly developed fiber optic TIA module that connects with traditional PPG sensors and/or fiber optic sensors [29]. These features have allowed the system to be adopted in a wide range of physiological studies investigating hemodynamic changes during mild hypothermia, occlusion, different hand elevations, and head down tilts [30]- [33].…”
Section: B Preliminary Evaluationmentioning
confidence: 99%
See 1 more Smart Citation