2023
DOI: 10.3390/s23073689
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Optimal Light Source Wavelength for Cuffless Blood Pressure Estimation Using a Single Photoplethysmography Sensor

Abstract: Routine blood pressure measurement is important for the early detection of various diseases. Recently, cuffless blood pressure estimation methods that do not require cuff pressurization have attracted attention. In this study, we investigated the effect of the light source wavelength on the accuracy of blood pressure estimation using only two physiological indices that can be calculated with photoplethysmography alone, namely, heart rate and modified normalized pulse volume. Using a newly developed photoplethy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 42 publications
0
1
0
Order By: Relevance
“…In the current Special Issue, the optimization of hardware and software systems for a reliable PPG signal acquisition and pre-processing was one of the main topics. The influence of the light source wavelength of the PPG sensor on the accuracy of blood pressure estimation was investigated by Toda et al [ 5 ], who proposed a new system based on four light-emitting diodes (near-infrared (NIR), red, green, and blue) acquiring multi-wavelength PPG signals from the index finger. NIR was found to be the most accurate wavelength for the estimation of systolic blood pressure from PPG signals, and blue was the best performing when they extracted diastolic blood pressure and mean arterial pressure.…”
Section: Contributionsmentioning
confidence: 99%
“…In the current Special Issue, the optimization of hardware and software systems for a reliable PPG signal acquisition and pre-processing was one of the main topics. The influence of the light source wavelength of the PPG sensor on the accuracy of blood pressure estimation was investigated by Toda et al [ 5 ], who proposed a new system based on four light-emitting diodes (near-infrared (NIR), red, green, and blue) acquiring multi-wavelength PPG signals from the index finger. NIR was found to be the most accurate wavelength for the estimation of systolic blood pressure from PPG signals, and blue was the best performing when they extracted diastolic blood pressure and mean arterial pressure.…”
Section: Contributionsmentioning
confidence: 99%