2018
DOI: 10.1089/jamp.2017.1369
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Lung Pharmacokinetic of the Novel PDE4 Inhibitor CHF6001 in Preclinical Models: Evaluation of the PreciseInhale Technology

Abstract: The PreciseInhale platform enabled the administration of CHF6001 powder with good accuracy and reproducibility, with low tracheal deposition. The new platform can be used at an early discovery stage to obtain inhalatory PK data for respirable aerosols of neat NCE powder without excipients and with minimal use of dry powder formulation work.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 25 publications
(14 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…The goal for further development is to use the ventilation data, in combination with the signal from the aerosol monitor instrument for active dose control of the aerosol, in the same manner as in the PI (PreciseInhale Ò ) dry powder application. (11) Drying of carrier air was accomplished with 800 mL silica gel in a drying column located upstream of the flow meter. After drying, the carrier air was filtered through a 65 mm filter pad (PARI, Germany) placed at the drying column exit to prevent silica gel dust from entering the exposure line.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The goal for further development is to use the ventilation data, in combination with the signal from the aerosol monitor instrument for active dose control of the aerosol, in the same manner as in the PI (PreciseInhale Ò ) dry powder application. (11) Drying of carrier air was accomplished with 800 mL silica gel in a drying column located upstream of the flow meter. After drying, the carrier air was filtered through a 65 mm filter pad (PARI, Germany) placed at the drying column exit to prevent silica gel dust from entering the exposure line.…”
Section: Methodsmentioning
confidence: 99%
“…1A). (11) Following such phantom exposures, a substance correlation factor can be defined correlating the optical and gravimetric mass flux of aerosol inhaled by the exposure subject. This correlation factor is then used by the software to control the individual exposures in real-time.…”
Section: Fig 1 (A)mentioning
confidence: 99%
See 1 more Smart Citation
“…Dry powder aerosols were generated with the PreciseInhale TM using an impactor nozzle and applying a generation pressure of 30 bar and a reset pressure of 12 bar (Fioni et al 2018).…”
Section: Materials and Aerosol Generationmentioning
confidence: 99%
“…The PreciseInhale TM (Inhalation Sciences Sweden AB, Stockholm, Sweden) aerosol exposure platform was developed to allow small-scale respirable aerosol exposures of different experimental models from in vitro to ex vivo/in vivo lung exposures starting with identical test aerosols. The platform has been used successfully for both air pollution research and the development of pharmaceuticals, as it allows the testing of various exposure modules using the same respirable aerosols (Fioni et al 2018). A direct comparison of results from different modules improves interpretation accuracy and reduces the need for costly crossover studies.…”
Section: Introductionmentioning