2018
DOI: 10.1371/journal.pone.0198830
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of lateral geniculate nucleus volume and diffusion tensor imaging in patients with normal tension glaucoma using 7 tesla magnetic resonance imaging

Abstract: BackgroundThere is evidence that glaucoma is a neurodegenerative disease involving the whole visual pathway. We prospectively examined potential benefits of volumetry of the lateral geniculate nucleus (LGN) and diffusion tensor imaging (DTI) using a new 7T scanner.Methods20 patients with normal tension glaucoma and 16 control individuals were examined. LGN volume and fractional anisotropy (FA) of the optic tract (OT) and the optic radiation (OR) and their correlation with RNFL (retinal nerve fiber layer) thick… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
28
0
5

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 30 publications
(35 citation statements)
references
References 28 publications
2
28
0
5
Order By: Relevance
“…The number of NeuN-positive cells was decreased in all the layers (A, A1, and C) projected from the OH eyes (Tables 1 and 2). Previously, decreased the number of neurons in the LGN in monkeys [7,44,45] and decreased LGN volume in humans [46] has been reported. Our findings in ferrets corroborate these results.…”
Section: Discussionmentioning
confidence: 98%
“…The number of NeuN-positive cells was decreased in all the layers (A, A1, and C) projected from the OH eyes (Tables 1 and 2). Previously, decreased the number of neurons in the LGN in monkeys [7,44,45] and decreased LGN volume in humans [46] has been reported. Our findings in ferrets corroborate these results.…”
Section: Discussionmentioning
confidence: 98%
“…Beim Glaukom ist das Volumen des CGL signifikant geringer als bei sehgesunden Kontrollprobanden (rechts: 60,4 vs. 87,7 mm 3 , p < 0,05; links: 61,8 vs. 88,8 mm 3 , p < 0,05; gemittelt: 60,9 vs. 88,3 mm 3 , p = 0,05). Es gibt eine starke positive Korrelation des Volumens des CGL mit der jeweiligen Gegenseite (r = 0,768, p = 0,001) [7] (▶ Abb. 2 und 3 A).…”
Section: Dreidimensionale Volumetrie Und Diffusionsgewichtete Ultrahounclassified
“…Die FA in der Sehstrahlung (4. Neuron) ist ebenfalls signifikant reduziert (rechts 0,41 vs. 0,70, p < 0,05; links 0,41 vs. 0,69, p < 0,05; gemittelt 0,41 vs. 0,69) [7] (▶ Abb. 3 B und C).…”
Section: Dreidimensionale Volumetrie Und Diffusionsgewichtete Ultrahounclassified
See 2 more Smart Citations