2004
DOI: 10.1016/j.jelechem.2004.04.006
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of ion-selective electrodes with neutral ionophores and ionic sites by EIS. I. Theory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2005
2005
2017
2017

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(14 citation statements)
references
References 42 publications
1
13
0
Order By: Relevance
“…To obtain an optimum working conditions, it is necessary to add a minimum concentration of mobile ionic sites in the sensing membrane. 25 The role of the lipophilic anion in cation-selective membranes containing an electrically neutral ionophore is to provide fixed negative sites in the membrane, which induce preselectivity to cations and exclude anions from the membrane, this phenomenon is called Donnan exclusion. 7 Then, the comparison of electrodes prepared by compositions 1, 3, and 5 shows the sensitivity is increasing as anion sites increased, while other compositions of weight ratios are fixed.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…To obtain an optimum working conditions, it is necessary to add a minimum concentration of mobile ionic sites in the sensing membrane. 25 The role of the lipophilic anion in cation-selective membranes containing an electrically neutral ionophore is to provide fixed negative sites in the membrane, which induce preselectivity to cations and exclude anions from the membrane, this phenomenon is called Donnan exclusion. 7 Then, the comparison of electrodes prepared by compositions 1, 3, and 5 shows the sensitivity is increasing as anion sites increased, while other compositions of weight ratios are fixed.…”
Section: Resultsmentioning
confidence: 99%
“…Therefore, the ratio of the anionic sites to ionophore in the membrane exceeds 90 mol %, the selectivity of the polymeric membrane electrode dropped dramatically. 25 Gabrielli et al studied the ratio of ionophore and anion sites in potassium ISE by impedance method in 2004. 25 They presented a conclusion on the ratio of the ionophore and anion sites in potassium ISE.…”
Section: Resultsmentioning
confidence: 99%
“…It appears at a pH testing solution, which slope at a concentration of 5% is somewhat higher than the concentration of 4%. 41,42 …”
Section: Effects Of Sodium Salt Of Poly(anethol Sulfonic Acid)mentioning
confidence: 99%
“…Most of them present steady-state analytical solutions restricted to only one type of system and/or fixed number of species, e.g. derived for liquid ionic exchanger [9][10][11][12][13], or neutral carrier membranes [14,15] where authors developed inter alia the analytical solution for complex impedance of such membrane.…”
Section: Npp Modelmentioning
confidence: 99%