2019
DOI: 10.1016/j.buildenv.2019.03.022
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of indoor air quality determinants in a field study using three different data streams

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
28
0
1

Year Published

2019
2019
2022
2022

Publication Types

Select...
5
2

Relationship

2
5

Authors

Journals

citations
Cited by 23 publications
(29 citation statements)
references
References 116 publications
0
28
0
1
Order By: Relevance
“…Bioaerosol measurements were performed in Building 1 (B1), Building 2 (B2), and Building 3 (B3) (Table 1) between 2011 and 2015, according to the timeline shown in Figure 1. Our study invited all residents from the three buildings to participate via brochures and communications from the building management, and the recruitment is described in more detail in earlier publications 52‐57 . B1 is an Energy Star certified residential building with an urban rooftop garden and a total of 128 apartments in two wings with six and seven floors.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Bioaerosol measurements were performed in Building 1 (B1), Building 2 (B2), and Building 3 (B3) (Table 1) between 2011 and 2015, according to the timeline shown in Figure 1. Our study invited all residents from the three buildings to participate via brochures and communications from the building management, and the recruitment is described in more detail in earlier publications 52‐57 . B1 is an Energy Star certified residential building with an urban rooftop garden and a total of 128 apartments in two wings with six and seven floors.…”
Section: Methodsmentioning
confidence: 99%
“…Our study invited all residents from the three buildings to participate via brochures and communications from the building management, and the recruitment is described in more detail in earlier publications. [52][53][54][55][56][57] B1 is an Energy Star certified residential building with an urban rooftop garden and a total of 128 apartments in two wings with six and seven floors. B1 has hot water baseboard heating supplied by a centralized boiler and natural air ventilation, predominantly using open windows.…”
Section: Study Buildings and Measurement Timelinementioning
confidence: 99%
“…In the reviewed studies, additional behavioral interventions to improve IAQ, such as changes in cleaning activities, decreased use of candles or incense, and increased ventilation if having pets, were less frequently identified. One study found that certain cleaning practices (vacuuming, dusting, or sweeping) resulted in higher indoor PM 2.5-10 levels, 54 and three studies 16,32,36 showed links of higher indoor particle counts and PM 2.5 and the use of candles/incense. Lastly, Doll et al 20 found correlations of pet presence with higher particle levels inside homes.…”
Section: Find Ing S and Discussionmentioning
confidence: 99%
“…[10][11][12] While the trade-off between energy efficiency and IAQ remains a design and operational challenge, the relevance of additional characteristics and factors affecting IAQ (eg, outdoor conditions, ambient pollutant properties and concentrations, as well as indoor occupant behaviors) have received increasing focus. [13][14][15][16] As a result, field studies have become more abundant in an attempt to parse the relative influence of various IAQ factors and to improve IAQ in real-world settings.…”
Section: Factors Affecting Iaqmentioning
confidence: 99%
See 1 more Smart Citation