2016
DOI: 10.1007/s11307-016-1035-9
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of Image Reconstruction Parameters of the Mediso nanoScan PC Small-Animal PET/CT Scanner for Two Different Positron Emitters Under NEMA NU 4-2008 Standards

Abstract: A high regularization level at 52 iteration updates and 30 min acquisition time were found to optimize most of the figures of merit investigated.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…This is most probably due to the fact that preclinical PET/MR systems were introduced recently in comparison with single PET and PET/CT scanners. Most studies in the past have estimated the outcome of in vivo studies solely based on the performance of the PET in phantoms which does not always predict the performance in animals [ 14 , 18 , 29 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…This is most probably due to the fact that preclinical PET/MR systems were introduced recently in comparison with single PET and PET/CT scanners. Most studies in the past have estimated the outcome of in vivo studies solely based on the performance of the PET in phantoms which does not always predict the performance in animals [ 14 , 18 , 29 31 ].…”
Section: Discussionmentioning
confidence: 99%
“…Several research groups [6][7][8][9][10][11] have published articles where they discussed about performance of preclinical PET scanner. However, there are no long-term performance monitoring, manufacturer reference values or acceptance test nor any description on how such evaluations were actually performed.…”
Section: Discussionmentioning
confidence: 99%
“…At an activity concentration of 13.5 kBq/mL, the recovery coefficients for 18 (21). Considering that the organs of ostrich embryos are naturally larger than those of chicken embryos (e.g., liver size: 15 vs. 2 cm 3 ) (18,22), it is conceivable that imaging is comparable.…”
Section: Discussionmentioning
confidence: 99%
“…This aspect has to be evaluated in future studies. Obviously, because of the small gantry size of 98.6 mm, the small-animal device does not allow the investigation of ostrich eggs (21).…”
Section: Discussionmentioning
confidence: 99%