2015
DOI: 10.1016/j.carbon.2015.05.091
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of electro-mechanical behavior of carbon nanotube yarns during tensile loading

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
11
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(12 citation statements)
references
References 26 publications
(43 reference statements)
1
11
0
Order By: Relevance
“…In Zhao et al, 26 a longitudinal gauge factor not exceeding 0.38 was reported, and in Abot et al, 27 0.9 was reported. The maximum value was found in Abu Obaid et al 28 in the range from 1.34 to 2 with the average value around 1.7, which is comparable to that obtained by traditional strain gauges. The main reason for this discrepancy is the low Young's modulus of CNT yarns (about 70 GPa) as compared with carbon fibers.…”
Section: Smart Textiles For Shmsupporting
confidence: 63%
See 1 more Smart Citation
“…In Zhao et al, 26 a longitudinal gauge factor not exceeding 0.38 was reported, and in Abot et al, 27 0.9 was reported. The maximum value was found in Abu Obaid et al 28 in the range from 1.34 to 2 with the average value around 1.7, which is comparable to that obtained by traditional strain gauges. The main reason for this discrepancy is the low Young's modulus of CNT yarns (about 70 GPa) as compared with carbon fibers.…”
Section: Smart Textiles For Shmsupporting
confidence: 63%
“…A review of the literature also showed some amount of work focused on the study of the properties of polymeric yarns with dispersed CNTs. [25][26][27][28] It has been shown that CNTs have great potential as strain gauges because their gauge factor is estimated to be 15, whereas the metal does not exceed 4. Some authors note that CNT yarns have comparable mechanical properties and superior electrical properties in comparison with carbon fibers.…”
Section: Smart Textiles For Shmmentioning
confidence: 99%
“…Further to measure the sensitivity of graphene-based BP/PVA, the gauge factor based on relative resistance change and strain is performed in a strain range of (ε ~ 4%), as 75-graphene-based BP/PVA starts to deform its shape after (ε ~ 4%) and linear relationship between strain and relative resistance change no longer holds 58 . The gauge factor itself is a slope of relative resistance change curve versus strain.…”
Section: Characterization Of Pva Infiltrated Graphene-based Bucky Papermentioning
confidence: 99%
“…33 the microstructural motion of a biphasic CNN is analysed under compression; in Abu Obaid et al . 34 the evolution of the helicoidal organization of the fibres of CNT yarns is observed under tension; and in Stallard et al . 35 straightening and buckling of fibres within direct-spun CNT mats submitted to very large tensile strains are reported.…”
Section: Introductionmentioning
confidence: 96%