Investigation of current variation effect on PLC channel characteristics of low-voltage high power busbar systems

Abstract: This paper aims to analyze communication characteristics of the high current low-voltage (LV) busbar systems in 1-50 MHz frequency range due to the fact that busbar as an integrated part of the overall Power Line Communications (PLC) channel, it is necessary to investigate its communication characteristics. Firstly, the modeling of a compact structure LV busbar system is described. Then, this system carried out by an Electromagnetic (EM) analysis simulation tool based on methods of moments (MoM). Channel chara… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
4
1

Relationship

2
3

Authors

Journals

citations
Cited by 5 publications
(9 citation statements)
references
References 26 publications
0
9
0
Order By: Relevance
“…Due to a busbar having three-phases, it can be defined as six different two-port network namely L1-N, L2-N, L3-N (phase to neutral) and L2-L1, L3-L1, L3-L2 (phase to phase) [1,2,25,26]. S-parameters measurements were made for all possible port connections.…”
Section: Measurement Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…Due to a busbar having three-phases, it can be defined as six different two-port network namely L1-N, L2-N, L3-N (phase to neutral) and L2-L1, L3-L1, L3-L2 (phase to phase) [1,2,25,26]. S-parameters measurements were made for all possible port connections.…”
Section: Measurement Setupmentioning
confidence: 99%
“…In the literature, there is a gap about the characterization of the busbar distribution systems for broadband PLC applications which should be closed. In particular, busbars should be analyzed as transmission lines [1,2]. In the literature, several techniques have been introduced to extract the transmission line parameters for different transmission lines (RLGC parameters, characteristic impedance Z c , and propagation constant γ).…”
Section: Introductionmentioning
confidence: 99%
“…While lossy transmission line models may equally be described in terms of characteristic impedance (Z c ) * Correspondence: zhasirci@ktu.edu.tr and propagation constant (γ), designers generally focus on RLGC parameters. Busbar systems may also be described as transmission lines [9,10] and represented with RLGC parameters as the other power cables. Many studies have examined the derivation of per-unit-length parameters for power cables.…”
Section: Introductionmentioning
confidence: 99%
“…Hasirci et al [10] presented the propagation characteristics of different current levels in copper conductor series busbar systems at 1-50 MHz. Some works [9,10] are simulation-based studies that require experimental validation.…”
Section: Introductionmentioning
confidence: 99%
“…Whereas lossy transmission line models may equally be described in terms of the characteristic impedance (Z c ) and propagation constant (γ), designers are generally focused on RLGC parameters. Judging from here, busbar system can also be described as a transmission line [2], [3] and can be represented with RLGC parameters as the other power cables. In the literature, there are many studies about power cables and extraction of the p.u.l.…”
mentioning