2010
DOI: 10.1016/j.hedp.2009.09.001
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of characteristics of hard x-rays produced during implosions of wire array loads on 1.6 MA Zebra generator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2011
2011
2016
2016

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 29 publications
(43 reference statements)
0
3
0
1
Order By: Relevance
“…Сравнительно эффективным средством гене рации рентгеновского излучения являются уста новки с использованием Z и Xпинча [5][6][7]. Эффект сжатия токового канала под действием магнит ного поля, индуцированного сильным током в тонких металлических проволоках, обеспечивает получение высокотемпературной плазмы, излу чающей в полный телесный угол в широком рент геновском диапазоне спектра, при эффективном размере фокуса около 10 мкм.…”
Section: Choosing the Source Of Radiationunclassified
See 1 more Smart Citation
“…Сравнительно эффективным средством гене рации рентгеновского излучения являются уста новки с использованием Z и Xпинча [5][6][7]. Эффект сжатия токового канала под действием магнит ного поля, индуцированного сильным током в тонких металлических проволоках, обеспечивает получение высокотемпературной плазмы, излу чающей в полный телесный угол в широком рент геновском диапазоне спектра, при эффективном размере фокуса около 10 мкм.…”
Section: Choosing the Source Of Radiationunclassified
“…A c o mp a r at ive ly e f fe c t ive tool of generating Xrays is the installation using Z and Xpinch [5][6][7]. The effect of compression of the c ur rent channel under t he i n fluence of a m ag net ic field induced by the strong cur rent in the thin metal wires pro duces hightemperature plasma emitting the full solid angle in a wide Xray spectrum with the effective focus size of about 10 µm.…”
Section: Choosing the Source Of Radiationmentioning
confidence: 99%
“…At the Nevada Terawatt Facility the Zebra z-pinch (1MA, 2MVolts, 80ns) was used to shoot single planar wire arrays [24][25][26] to assess the level of debris present and background proton noise that threaten clean proton radiography. The detector of choice was CR39 due to its quasi insensitivity to x-rays, electron and gamma rays [27,28].…”
Section: A High Debris Environmentmentioning
confidence: 99%
“…The hard X-ray yield from these wire arrays is on the order of several Joules, and depends on the wire material and the load geometry but only weakly varies with load mass. The cold spectral lines in the hard X-ray region appear only when an electron beam interacts with the relatively cold material of the load [8,9]. Further studies show that both the current and the energy of the beam electrons are most intense at the stagnation stage and at axial nonuniformities, and that the radiation produced by these electrons increases approximately linearly with the wires' atomic number.…”
Section: Introductionmentioning
confidence: 99%