2001
DOI: 10.1016/s0002-9149(01)01855-0
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
68
0
9

Year Published

2004
2004
2017
2017

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 172 publications
(83 citation statements)
references
References 17 publications
6
68
0
9
Order By: Relevance
“…7 In our study, the overall scan time varied from 8 seconds to 12 seconds, significantly decreased as compared to the previous 4-slice (40 seconds) and 16-slice (30 seconds) scanners. [8][9][10] In our study, because of increased scan speed and volume coverage, in all patients we could cover the origin of LIMA grafts in spite of maintaining the breath hold within reasonable limits.…”
Section: Discussionmentioning
confidence: 96%
“…7 In our study, the overall scan time varied from 8 seconds to 12 seconds, significantly decreased as compared to the previous 4-slice (40 seconds) and 16-slice (30 seconds) scanners. [8][9][10] In our study, because of increased scan speed and volume coverage, in all patients we could cover the origin of LIMA grafts in spite of maintaining the breath hold within reasonable limits.…”
Section: Discussionmentioning
confidence: 96%
“…Four-row CT provided an anisotropic resolution, which oftentimes did not depict the distal anastomosis, and 38% of the patent grafts could not be evaluated because of respiratory/ Coronary Artery Bypass Graft Surgerymotion/metallic clip artifacts [10,11]. Sixteen-row CT scanners improved assessment of occlusion/significant stenosis; however, about 20% were not assessable because of artifacts [12,13].…”
Section: Accuracy Of Different Generations Of Ct In Coronary Bypass Gmentioning
confidence: 99%
“…One method for limiting dose is using an electrocardiogram-dependent tube current modulation in which the tube pulses radiation triggered by R waves detected by electrocardiogram [54]. This method was used by Ropers and colleagues and resulted in radiation doses averaging 7.45 mSv for men and 10.24 mSv for women [55]. However, this technique does not allow retrospective reconstruction of images in additional phases of the cardiac cycle and will result in suboptimal image quality whenever there is a slight arrhythmia.…”
Section: Radiation Exposurementioning
confidence: 99%