2015
DOI: 10.1109/tps.2015.2420679
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of a Commercial Atmospheric Pressure Plasma Jet by a Newly Designed Calorimetric Probe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
23
0
2

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(26 citation statements)
references
References 15 publications
1
23
0
2
Order By: Relevance
“…After reaching a minimum at 5 mm distance, the contact angle increases again. This trend was expected and follows the energy influx measurements performed by Kewitz et al using the same device. A correlation between the energy influx and surface activation could be seen.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…After reaching a minimum at 5 mm distance, the contact angle increases again. This trend was expected and follows the energy influx measurements performed by Kewitz et al using the same device. A correlation between the energy influx and surface activation could be seen.…”
Section: Resultsmentioning
confidence: 99%
“…The templates are mounted on a microscope slide that is held upside down above the plasma by reduced pressure. For the aerographite templates, an APPJ (Plasmatreat) consisting of a FG5001 generator, a HTR12 transformer, and a RD1004 nozzle was chosen (Figure ) . At the nozzle, a precursor inlet was mounted for introducing hexamethyldisiloxane (HMDSO) into the effluent jet.…”
Section: Methodsmentioning
confidence: 99%
“…An additional uncertainty of about 10% is induced by the calibration of the probe. Using the Gaussian profile of the jet obtained at the same parameters with air (standard deviations of 3.35 ± 0.06 mm and 3.47 ± 0.06 mm in x-and ydirections [8]) and regarding the probe diameter of 5 mm, this results in a total energy flux from the jet of 1.61 ± 0.16 kW. This value is comprehensible considering the primary power of 2.3 kW used for this experiment, since a lower value was expected due to different losses in the plasma jet system and only a fraction of the total energy is transferred to the surface.…”
Section: Modified Analytical Methods At High Energy Fluxes and Experimmentioning
confidence: 99%
“…It was already shown that for the investigation of atmospheric pressure plasma jets with a large power consumption changes in the design of the probe are necessary [8]. These adaptions allow to handle the high mechanical and thermal stress of the probe induced by the investigated high power atmospheric pressure plasma jet from the company Plasmatreat.…”
Section: Introductionmentioning
confidence: 99%
“…optical emission spectroscopy) za detekciju kemijski aktivnih vrsta, deaktivacija biofilmova na Ti diskovima promatrana je fluorescencijskom mikroskopijom kao i pretražnim elektronskim mikroskopiranjem (SEM, engl. scanning electron microscopy), termalne sonde koriste se za mjerenje temperature plazme i određivanje prenesene toplinske energije, a spektrometrijom izotopnih omjera promatraju se izotopne promjene u plazmom tretiranim tekućinama [11][12][13][14][15][16][17] . Nastojanja da se konstruira što bolji instrument za CAP generiranje rezultirala su mnogobrojnom aparaturom različite konfiguracije i posljedično, mnogobrojnim geometrijama plazme: plazmena igla (engl.…”
Section: Plazma U Fiziciunclassified