“…One limitation of the study consists in the restricted field of view of the 4DMRI (12.5 cm in the right-left direction), which was due to imaging constraints and the trade-off between temporal and spatial resolution. 9,29 The availability of 4DMRI data with extended field of view 7,30 would lead to better DIR performance and improved motion model estimations over the entire irradiated patient anatomy. Another limitation is the small number of patient data sets acquired for our analysis.…”
Section: Discussionmentioning
confidence: 99%
“…One limitation of the study consists in the restricted field of view of the 4DMRI (12.5 cm in the right-left direction), which was due to imaging constraints and the trade-off between temporal and spatial resolution. 9,29 The availability of 4DMRI data with extended field of view 7,30 would lead to better DIR performance and improved motion model estimations over the entire irradiated patient anatomy. Another limitation is the small number of patient data sets acquired for our analysis.…”
Section: Discussionmentioning
confidence: 99%
“…The end‐exhale CT from the pCT and end‐exhale MR were deformably registered with Bspline DIR (plastimatch.org), thus obtaining a 3D DVF limited to the MR FOV. The DVF was then extended to the FOV of the entire patient anatomy by replicating the motion components at the boundary of the FOV (i.e., in correspondence to the two extreme sagittal slices) to the surrounding voxels 16 . The pCT was therefore deformed according to the resulting DVF to match the abdominal anatomy of the end‐exhale MR, yielding the reference vCT (Figure 1a).…”
Section: Methodsmentioning
confidence: 99%
“…The 3D DVF corresponding to each pair was estimated by propagating to all adjacent planes the right–left and superior–inferior motion components from the coronal DVF, and the antero‐posterior information from the sagittal DVF 26 . Due to the abdominal compression applied at CNAO, we assumed negligible motion of the spinal cord and ribs, thus considering the estimated motion only within the lower‐thorax and abdomen 13–16 . The reference vCT was finally deformed according to the resulting 3D DVF, thus reconstructing a virtual 3D CT corresponding to each pair of 2D cine‐MRI frames (Figure 1c).…”
Section: Methodsmentioning
confidence: 99%