2023
DOI: 10.1016/j.forc.2023.100534
|View full text |Cite
|
Sign up to set email alerts
|

Investigating the effect of substitution location on fentanyl analog identification for methyl-substituted fentanyl analogs using GC-EI-MS

Alexis Pollard,
J. Tyler Davidson
Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 30 publications
0
0
0
Order By: Relevance
“…11 Since then, numerous studies have focused on characterizing fragmentation pathways of fentanyl and its many analogues with tandem MS, [12][13][14][15][16] including by both electrospray ionization (ESI) [17][18][19][20][21] and electron ionization (EI). [22][23][24][25][26] This has also led to the development of highresolution mass spectrometry (HRMS) methods becoming more routinely implemented for identification of fentanyl analogues and other new psychoactive substances (NPS), 27,28 along with the development of software tools to aid in screening. 29,30 Recently, ion mobility and mass spectrometry (IM-MS) have been coupled as a more comprehensive method for drug detection and quantification.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…11 Since then, numerous studies have focused on characterizing fragmentation pathways of fentanyl and its many analogues with tandem MS, [12][13][14][15][16] including by both electrospray ionization (ESI) [17][18][19][20][21] and electron ionization (EI). [22][23][24][25][26] This has also led to the development of highresolution mass spectrometry (HRMS) methods becoming more routinely implemented for identification of fentanyl analogues and other new psychoactive substances (NPS), 27,28 along with the development of software tools to aid in screening. 29,30 Recently, ion mobility and mass spectrometry (IM-MS) have been coupled as a more comprehensive method for drug detection and quantification.…”
Section: Introductionmentioning
confidence: 99%
“…Wichitnithad et al first investigated the tandem mass spectrometry (MS/MS) pattern of fentanyl, revealing isobaric fragments that could complicate its identification 11 . Since then, numerous studies have focused on characterizing fragmentation pathways of fentanyl and its many analogues with tandem MS, 12–16 including by both electrospray ionization (ESI) 17–21 and electron ionization (EI) 22–26 . This has also led to the development of high‐resolution mass spectrometry (HRMS) methods becoming more routinely implemented for identification of fentanyl analogues and other new psychoactive substances (NPS), 27,28 along with the development of software tools to aid in screening 29,30 …”
Section: Introductionmentioning
confidence: 99%