Investigating Cardiorespiratory Interaction Using Ballistocardiography and Seismocardiography—A Narrative Review

Abstract: Ballistocardiography (BCG) and seismocardiography (SCG) are non-invasive techniques used to record the micromovements induced by cardiovascular activity at the body’s center of mass and on the chest, respectively. Since their inception, their potential for evaluating cardiovascular health has been studied. However, both BCG and SCG are impacted by respiration, leading to a periodic modulation of these signals. As a result, data processing algorithms have been developed to exclude the respiratory signals, or re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 181 publications
(301 reference statements)
0
10
0
Order By: Relevance
“…More recently, these techniques have been used in domains such as atrial fibrillation ( 10 ) and hypertension detection ( 11 ), heart failure monitoring ( 12 , 13 ), cardiorespiratory fitness assessment ( 14 , 15 ), and many others. Recent advances in the field of SCG were published by Taebi et al ( 16 ).…”
Section: Introductionmentioning
confidence: 99%
“…More recently, these techniques have been used in domains such as atrial fibrillation ( 10 ) and hypertension detection ( 11 ), heart failure monitoring ( 12 , 13 ), cardiorespiratory fitness assessment ( 14 , 15 ), and many others. Recent advances in the field of SCG were published by Taebi et al ( 16 ).…”
Section: Introductionmentioning
confidence: 99%
“…Subsequent researchers, such as Henderson [63], Heald and Tucker [64], Starr and Krumbhaar [65], and Rubenstein [66], among others, have explored the influence of respiration on the BCG signal. Unlike SCG, micro-motion is not limited to the chest but extends to the entire body surface [67]. The BCG component also encompasses movement along all three axes and can be measured as acceleration, velocity, displacement, or force signal [53].…”
Section: Seismocardiography Ballistocardiography and Similar Methodsmentioning
confidence: 99%
“…While the impact of respiration on ECG [68] has been extensively studied, research on the effects of respiration on SCG and BCG lags. According to a systematic review by Han et al [69], only a small percentage of studies focus on respiratory monitoring [67]. BCG is primarily influenced by cyclical changes in intrathoracic pressure resulting from pulmonary ventilation [18], serving as a source of respiratory-cardiovascular coupling [70].…”
Section: Seismocardiography Ballistocardiography and Similar Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…As presented in the methods, the reliability of rotational kinetic energy was not investigated in the current work; therefore, the results obtained here are only relevant to linear kinetic energy. Previous studies [40,41] have established that respiration markedly influences the metrics obtained from SCG. However, this study did not investigate the repeatability of metrics derived from a specific respiration phase.…”
Section: Limitationsmentioning