2012 3rd IEEE International Symposium on Power Electronics for Distributed Generation Systems (PEDG) 2012
DOI: 10.1109/pedg.2012.6253999
|View full text |Cite
|
Sign up to set email alerts
|

Inverter modelling techniques for protection studies

Abstract: Abstract-Traditional fault calculation techniques are not capable of accurately modelling the short-circuit behaviour of inverter interfaced distributed generation (IIDG). As the share of IIDG continues to rise, more accurate fault simulations are required. This paper gives an overview of fault calculation techniques described in literature. All techniques are evaluated from the viewpoint of protection studies in medium and low voltage grids with a high share of IIDG. The averaged value modelling technique is … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(10 citation statements)
references
References 25 publications
0
8
0
Order By: Relevance
“…In this mode the harmonics are considered to be totally eliminated; consequently, calculation complexity is dramatically reduced. From the perspective of power system dynamic study, the average model is sufficient to appropriately mimic the realistic VSC's AC fault response [10]. Therefore, in this paper, the time average model is selected to analyse of the VSC fault performance.…”
Section: ) Time Average Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…In this mode the harmonics are considered to be totally eliminated; consequently, calculation complexity is dramatically reduced. From the perspective of power system dynamic study, the average model is sufficient to appropriately mimic the realistic VSC's AC fault response [10]. Therefore, in this paper, the time average model is selected to analyse of the VSC fault performance.…”
Section: ) Time Average Modelmentioning
confidence: 99%
“…Reference value of can be determined by the desired reference value of AC real power: (10) Or by the desired reference value of DC voltage: (11) The reference value of can be determined by the desired reference value of AC reactive power:…”
Section: Outer Control Loopmentioning
confidence: 99%
“…These techniques range from using full time domain modelling that is very accurate but computationally heavy to more simple methods that sacrifice some accuracy for speed [5]. Focus in this paper is put on the latter type.…”
Section: Introductionmentioning
confidence: 99%
“…Authors [1], [2], [3], [4], [5] all present different control diagrams with the common goal of simulating a constant power grid-connected IIDG. An accurate representation of the control scheme of an IIDG NOTICE: this is the authors' version of a work that was accepted for publication.…”
Section: Introductionmentioning
confidence: 99%
“…A single unified representation of the fault response for the short term transient of an IIDG unit is difficult as the thermal dynamics of the inverter must be accurately modelled in addition to the control and power dynamics of the IIDG and grid. The variety of fault current data gathered by [8] and the range of control schemes presented by authors [1], [2], [3], [4], [5] is testament to the impracticality of deriving a unified detailed model of short term transients. The FAT provides a means of approximating the fault response of IIDG for use in analysing DN line protection schemes without requiring an in-depth understanding of an IIDG unit's control structure.…”
Section: Introductionmentioning
confidence: 99%