Abstract:Purpose
In this study, we developed in-house software to evaluate the effect of the lead block (LB)-inserted spacer on the mandibular dose in interstitial brachytherapy (ISBT) for tongue cancer. In addition, an inverse planning algorithm for LB attenuation was developed, and its performance in mandibular dose reduction was evaluated.
Methods
Treatment plans of 30 patients with tongue cancer treated with ISBT were evaluated. The prescribed dose was 54 Gy/9 … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.