2019
DOI: 10.1109/tie.2018.2880720
|View full text |Cite
|
Sign up to set email alerts
|

Introduction and Advantage of Space Opposite Vectors Modulation Utilized in Dual Two-Level Inverters With Isolated DC Sources

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 32 publications
(10 citation statements)
references
References 36 publications
0
10
0
Order By: Relevance
“…When ZSC flows, which is caused by the generated zero‐sequence voltage (ZSV) on the path provided by the structure of single dc source D2L‐VSI, using D2L‐VSIs with isolated dc sources is able to eliminate ZSC completely since there is not any path for ZSC to flow [11, 22]. By using an isolating transformer to isolate dc sources, common‐mode current (CMC) could not flow from the frame of electric motors to ground, star‐point of the three‐phase supply, and finally mid‐point of the dc‐link capacitors due to the fact that the secondary windings are not grounded [23]. Although D2L‐VSIs with two isolated dc sources do not suffer from the ZSC and CMC – similar to other kinds of inverters, shaft voltage, bearing currents – they contain capacitive bearing current (d v /d t ) and electric discharge machining (EDM) currents.…”
Section: Introductionmentioning
confidence: 99%
“…When ZSC flows, which is caused by the generated zero‐sequence voltage (ZSV) on the path provided by the structure of single dc source D2L‐VSI, using D2L‐VSIs with isolated dc sources is able to eliminate ZSC completely since there is not any path for ZSC to flow [11, 22]. By using an isolating transformer to isolate dc sources, common‐mode current (CMC) could not flow from the frame of electric motors to ground, star‐point of the three‐phase supply, and finally mid‐point of the dc‐link capacitors due to the fact that the secondary windings are not grounded [23]. Although D2L‐VSIs with two isolated dc sources do not suffer from the ZSC and CMC – similar to other kinds of inverters, shaft voltage, bearing currents – they contain capacitive bearing current (d v /d t ) and electric discharge machining (EDM) currents.…”
Section: Introductionmentioning
confidence: 99%
“…The windings of the secondary side of the transformer are connected to the utility grid with star configuration. The most important advantage of utilizing dual inverters is lower output voltage harmonics, which results in a reduced size of the inductance filter; therefore, the overall cost could be reduced [14].…”
Section: Dual Inverter Topologymentioning
confidence: 99%
“…It leads to a reduction in switching losses and lower switching frequency [15]. The advantage of implementing two isolated DC link voltage sources is the elimination of zero sequence current (ZSC) [14]. Another benefit of dual inverters compared to a traditional two-level inverter is its capability in fault tolerance.…”
Section: Dual Inverter Topologymentioning
confidence: 99%
“…This is obviously due to the increasing level of PV penetration on the grid at various voltage levels. In its simplest form, a SI is defined as a power electronic device that converts a DC power to an AC [10,11] with monitoring, communication and control capabilities. Modern SIs are intelligent microprocessor-based which allows for Ethernet/LAN/WAN connectivity [12].…”
Section: Introductionmentioning