2020
DOI: 10.1167/tvst.9.12.10
|View full text |Cite
|
Sign up to set email alerts
|

Intrinsic Optical Properties of Boston Keratoprosthesis

Abstract: To benchmark the optical performance of Boston Keratoprosthesis (B-KPro). Methods: Back focal lengths (BFL) of B-KPros for various eye axial lengths were measured using an optical bench, International Organization for Standardizationcertified for intraocular lens characterization, and compared against manufacturer's specification. The modulation transfer function (MTF) and the resolution efficiencies were measured. The theoretical geometry-dependent higher-order aberrations (HOA) were calculated. The devices w… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 44 publications
(61 reference statements)
0
7
0
Order By: Relevance
“…The Boston Keratoprosthesis (KPro) is the most widely used artificial cornea, and its optical properties have been described previously. [2][3][4][5][6][7]10 It is sketched in profile in Figure 1b, and details of the design are provided by Sayegh et al, 2 Helms et al 4 and Hui et al 7 (although the parameters may not always be listed correctly). The material is rigid polymethyl-methacrylate (PMMA), which has a much higher refractive index than the natural cornea (1.492 compared to 1.376).…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…The Boston Keratoprosthesis (KPro) is the most widely used artificial cornea, and its optical properties have been described previously. [2][3][4][5][6][7]10 It is sketched in profile in Figure 1b, and details of the design are provided by Sayegh et al, 2 Helms et al 4 and Hui et al 7 (although the parameters may not always be listed correctly). The material is rigid polymethyl-methacrylate (PMMA), which has a much higher refractive index than the natural cornea (1.492 compared to 1.376).…”
Section: Methodsmentioning
confidence: 99%
“…The Boston Keratoprosthesis (KPro) is the most widely used artificial cornea, and its optical properties have been described previously 2–7,10 . It is sketched in profile in Figure , and details of the design are provided by Sayegh et al ., 2 Helms et al 4 .…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations