2018
DOI: 10.1016/j.mri.2018.05.013
|View full text |Cite
|
Sign up to set email alerts
|

Intravoxel incoherent motion diffusion-weighted magnetic resonance imaging in characterization of axillary lymph nodes: Preliminary animal experience

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 43 publications
0
9
0
Order By: Relevance
“…This difference might be ascribed to various factors. Although f is mainly affected by relaxation effects and the T2 contribution [17, 27], the MR system, post-processing software, and b value distribution also influence the estimation of this parameter [15, 28].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…This difference might be ascribed to various factors. Although f is mainly affected by relaxation effects and the T2 contribution [17, 27], the MR system, post-processing software, and b value distribution also influence the estimation of this parameter [15, 28].…”
Section: Discussionmentioning
confidence: 99%
“…However, some studies reported that positive LNs had higher D * values than negative LNs [28, 29]. In the IVIM model, the parametric calculation is affected by the distribution of b values [15, 28]; the inclusion of a greater number of b values lower than 200 s/mm 2 improves the characterization of the pseudo-diffusion effect [30, 31]. Although we used nine b values of less than 200 s/mm 2 , D * exhibited the lowest ICC of the IVIM-MRI parameters, but its utility was still unclear.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…33,34 Beyond simple summary statistics, histogram and spatial analyses within lesions further increase the demand for high-quality data at a voxel level, or the need for utilising prior assumptions of DWI parameter behaviour. 28,29,35 Some research articles report that the IVIM model provides clinically useful biomarkers [36][37][38][39][40][41] in breast, but a closer reading of some studies shows them supporting the use of D only, and not the pseudodiffusion parameters f and D*. [36][37][38]40 Results in these studies might therefore better be described as using a perfusion-insensitive ADC (and not IVIM), which can be acquired using only two b-values (e.g.…”
Section: Discussionmentioning
confidence: 99%