1994
DOI: 10.1902/jop.1994.65.3.255
|View full text |Cite
|
Sign up to set email alerts
|

Intrapulpal Temperatures During Pulsed Nd:YAG Laser Treatment of Dentin, In Vitro

Abstract: Lasers are being used for soft tissue removal, caries removal, and treatment of root surface sensitivity. One concern for laser safety is that the heat produced at the irradiated root surface may diffuse to the pulp causing irreversible pulpal damage. To test this heat diffusion, copper-constantan thermocouples were inserted into the radicular pulp canals of extracted teeth. Simulating direct exposure which might occur during gingival excision, superficial caries removal, and modification of the dentin surface… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
53
0
7

Year Published

1997
1997
2017
2017

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 104 publications
(65 citation statements)
references
References 18 publications
4
53
0
7
Order By: Relevance
“…However, treatment effects must be well controlled when using black ink as absorption enhancer. It was reported that irradiation at 2 W and 20 pps for 10 sec induced pulpal temperature rises through 2 mm of remaining dentine thickness of 13.4 aeC (White et al 1994). Using the CO 2 laser, no damage was reported after pulpal exposure to 3 W of power for 2 s in the CW mode using monkeys and dogs (Melcer et al 1985).…”
Section: Effect Of Laser Irradiation To Dental Pulpmentioning
confidence: 96%
“…However, treatment effects must be well controlled when using black ink as absorption enhancer. It was reported that irradiation at 2 W and 20 pps for 10 sec induced pulpal temperature rises through 2 mm of remaining dentine thickness of 13.4 aeC (White et al 1994). Using the CO 2 laser, no damage was reported after pulpal exposure to 3 W of power for 2 s in the CW mode using monkeys and dogs (Melcer et al 1985).…”
Section: Effect Of Laser Irradiation To Dental Pulpmentioning
confidence: 96%
“…This risk can exist through the penetration of short wavelengths or the conductive heat effects arising from long wavelength char that is super-heated. [5][6][7][8][9] It is advisable, therefore, to assess the thickness, vascularity and position of any target 6,[10][11][12] during the removal of a giant cell granuloma. Laser therapy has been cited as a possible modality in treating this condition.…”
Section: Laser-tissue Interaction and Keratinised Mucosa -Risk Analysismentioning
confidence: 99%
“…The energy parameters used in our study, which were 80 mJ and 10 Hz, are considered safe, not causing injuries to the pulp or necrosis. White et al 25 conducted a study in which various power parameters were tested to evaluate the temperature in the pulp chamber when applied at the pulpal cavity preparation wall in dentin. Those evaluations were conducted with a distance of 0.2 to 2 mm from the pulp, and the temperature was measured by thermocouples.…”
Section: Discussionmentioning
confidence: 99%
“…Those parameters were based on previous studies and considered safe, not causing injuries to the pulp. 8,24,25 After that, light curing of the adhesive was performed for 10 seconds. In Group L, only the irradiation of Nd:YAG laser over enamel surface was performed, using the same parameters described earlier, while Group C received no treatment (control).…”
Section: Surface Treatmentmentioning