Intraocular Pressure Study in Ex Vivo Pig Eyes by the Laser-Induced Cavitation Technique: Toward a Non-Contact Intraocular Pressure Sensor

Abstract: Traditional applanation tonometry techniques lack the necessary accuracy and reliability for measuring the intraocular pressure (IOP), and there is still a need for a reliable technique for in vivo diagnosis. A single laser-induced cavitation bubble event was optically monitored in order to precisely measure the first collapse time of the cavitation bubble, which presents a direct dependence on the liquid pressure. This can certainly be done within the IOP range. We now extend the partial transmittance modulat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
2
2

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(8 citation statements)
references
References 28 publications
0
8
0
Order By: Relevance
“…The device can be made compact, is potentially mobile, and is highly accurate even without preliminary calibration or preliminary information on the tested eye. We succeeded in IOP biomonitoring of 24 eyes of a living creature having characteristics that are closest to the human eye 51,52 , demonstrating high IOP measurement accuracy and potential clinical utility.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…The device can be made compact, is potentially mobile, and is highly accurate even without preliminary calibration or preliminary information on the tested eye. We succeeded in IOP biomonitoring of 24 eyes of a living creature having characteristics that are closest to the human eye 51,52 , demonstrating high IOP measurement accuracy and potential clinical utility.…”
Section: Discussionmentioning
confidence: 99%
“…This methodology was tested on artificial eyes as well as on fisheyes. We chose a set of 24 pig eyes for testing for two reasons: they represent a suitable animal model for glaucoma research due to the similarities between the pig eye and the human eye when subjected to chronically increased intraocular pressure; and there is a greater availability of pig eyes compared to nonhuman primate eyes 51,52 .…”
Section: Comparison Between the Remote Photonic Validation Methods An...mentioning
confidence: 99%
See 3 more Smart Citations