1998
DOI: 10.1097/00061198-199810000-00006
|View full text |Cite
|
Sign up to set email alerts
|

Intraocular Pressure Control after Contact Transscleral Diode Cyclophotocoagulation in Eyes with Intractable Glaucoma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

10
49
2
2

Year Published

2001
2001
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 51 publications
(63 citation statements)
references
References 0 publications
10
49
2
2
Order By: Relevance
“…4,22 The results of our study reveal a drop of IOP of about 53%, which compares favourably with the 30-50% range that has been reported in the literature. 5,6,14 The percentage of patients achieving an IOP of 21 mmHg, or less was 75% at 6 months, and 72.2% at the last follow-up; this is also in agreement with the figures of 38-95% in the literature. 5,6 Most importantly, is the maintenance of the pressure lowering effect over the mean follow-up of 14 months, without the need for multiple retreatments.…”
Section: Eyesupporting
confidence: 90%
See 3 more Smart Citations
“…4,22 The results of our study reveal a drop of IOP of about 53%, which compares favourably with the 30-50% range that has been reported in the literature. 5,6,14 The percentage of patients achieving an IOP of 21 mmHg, or less was 75% at 6 months, and 72.2% at the last follow-up; this is also in agreement with the figures of 38-95% in the literature. 5,6 Most importantly, is the maintenance of the pressure lowering effect over the mean follow-up of 14 months, without the need for multiple retreatments.…”
Section: Eyesupporting
confidence: 90%
“…In 25% of the study patients vision improved by 2 or more Snellen lines; 13.8% suffered a comparable loss, while the rest remained unchanged. These are promising figures when compared to those in other studies, 14,17 and this may be partly related to the higher percentage of patients with relatively good visual acuity enrolled in this study. Only few painful eyes with very little vision were included.…”
Section: Eyesupporting
confidence: 54%
See 2 more Smart Citations
“…Brancato et al (1995) 48 Transscleral 20.7 AE 8 70.8% (IOP < 21 mmHg) Kosoko et al (1996) 27 Transscleral 19 84% (IOP reduction > 20% at 1 year) 62% (IOP reduction > 20% at 2 years) Bloom et al (1997) 210 Transscleral 10 66% (IOP < 22 mmHg) Chen et al (1997) 68 Endoscopic 12.9 90% (IOP < 21 mmHg) Hamard et al (1997) 50 Transscleral 19.4 AE 9.1 66% (IOP < 20 mmHg) Yap-Veloso et al (1998) IOP, intra-ocular pressure.…”
Section: Retreatmentmentioning
confidence: 99%