2015
DOI: 10.1016/j.jcrs.2014.05.035
|View full text |Cite
|
Sign up to set email alerts
|

Intraocular lens opacification after corneal endothelial keratoplasty: Electron microscopy and x-ray element spectroscopy analysis

Abstract: No author has a financial or proprietary interest in any material or method mentioned.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
13
0
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 23 publications
(14 citation statements)
references
References 6 publications
0
13
0
1
Order By: Relevance
“…Although all four cases had rebubbling in this series, 1 in our recently published UK series only two of the five cases had rebubbling. 4 In our series, all five cases were also hydrophilic acrylic IOL's, although only one was a Rayner implant highlighting that this problem relates to hydrophilic acrylic material regardless of the manufacturer (other IOL's that opacified included Zeiss, STABIBAG; Lenstec, LH 3000; Bausch and Lomb, MI60 and Bausch and Lomb, Akreos). 4 We agree with the authors that patients requiring cataract surgery who are at risk of corneal endothelial failure (typically those with Fuchs' endothelial dystrophy)…”
mentioning
confidence: 67%
“…Although all four cases had rebubbling in this series, 1 in our recently published UK series only two of the five cases had rebubbling. 4 In our series, all five cases were also hydrophilic acrylic IOL's, although only one was a Rayner implant highlighting that this problem relates to hydrophilic acrylic material regardless of the manufacturer (other IOL's that opacified included Zeiss, STABIBAG; Lenstec, LH 3000; Bausch and Lomb, MI60 and Bausch and Lomb, Akreos). 4 We agree with the authors that patients requiring cataract surgery who are at risk of corneal endothelial failure (typically those with Fuchs' endothelial dystrophy)…”
mentioning
confidence: 67%
“…Despite the marked progress in the field of new materials and intraocular implant production technology, the incidence of IOL opacification is common. [345678910111213141516] IOL opacification is a rare but significant complication after DSAEK. The incidence of IOL opacification after DSAEK ranged from approximately 5% of 160 eyes (8 eyes)[11] to 9.7% of 154 eyes (15 eyes)[7] in a large number of patients.…”
Section: Discussionmentioning
confidence: 99%
“…Possible risk factors include an inflammatory reaction after multiple surgical procedures disrupting the blood–aqueous barrier,[4815] injection of exogenous air or gas into the AC,[61113] rebubbling after DSAEK,[10121415] and implantation of acrylic hydrophilic IOLs. [34578910111213141516]…”
Section: Discussionmentioning
confidence: 99%
“…Dabei kann es nach DSAEK in 7-20% und nach DMEK in 33-81 % der Fälle [5] bei einer frühen Transplantatdislokation notwendig sein, die Vorderkammer wiederholt mit Luft füllen zu müssen, um eine dauerhafte Transplantatanlage zu erreichen. Dies könnte im Zusammenhang damit stehen, dass jüngst vereinzelt über Kunstlinsentrübungen nach hinterer lamellärer Keratoplastik berichtet wurde [3,[6][7][8][9][10][11][12][13]. Nachdem auch an der Klinik für Augenheilkunde einzelne Fälle von Kunstlinsentrübungen nach hinterer lamellärer Keratoplastik aufgefallen waren, wurden alle digitalen Akten von Patienten, die in den vergangenen Jahren eine perforierende Keratoplastik, eine DSAEK, eine DMEK oder nur eine Kataraktoperation erhalten hatten hinsichtlich der Auftretens einer Kunstlinsentrübung überprüft, um einen Anhalt für die Häufigkeit dieser schwerwiegenden Komplikation zu bekommen.…”