2009
DOI: 10.1016/j.jcin.2008.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Intracoronary Electrocardiogram Recording With a Bare-Wire System

Abstract: We demonstrated a facile method to record IcECG with a guidewire with a polymer-coated shaft. The IcECG is a useful method for predicting post-procedural myocardial injuries.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
6
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(8 citation statements)
references
References 30 publications
1
6
0
Order By: Relevance
“…The present method is more comprehensive, however, as it provides a base for demonstrating the exact zone location source of possible troponin rise after intervention. In the subgroup of our patients with undetectable baseline troponin values, as in the cited studies, we demonstrated higher sensitivity and better negative predictive value (100%) in comparison with previous studies, with a slightly lower specificity (91% in our study vs. 95% in the Balian et al [8] study and 92% in the study by Uetani et al [10]). Since a different distribution of icECG shifts exists in the MB, this may explain the different sensitivity and specificity detected in previous studies.…”
Section: Discussionsupporting
confidence: 72%
See 4 more Smart Citations
“…The present method is more comprehensive, however, as it provides a base for demonstrating the exact zone location source of possible troponin rise after intervention. In the subgroup of our patients with undetectable baseline troponin values, as in the cited studies, we demonstrated higher sensitivity and better negative predictive value (100%) in comparison with previous studies, with a slightly lower specificity (91% in our study vs. 95% in the Balian et al [8] study and 92% in the study by Uetani et al [10]). Since a different distribution of icECG shifts exists in the MB, this may explain the different sensitivity and specificity detected in previous studies.…”
Section: Discussionsupporting
confidence: 72%
“…Despite the lower risk patient cohort, the frequency of postprocedural enzyme increase was almost identical to our patient population, although no data were provided about sensitivity and specificity of method regarding > 5 × N troponin I increase. In 339 patients with non-bifurcation PCI of non-complex lesions probed with icECG, Uetani et al [10] demonstrated sensitivity of 55%, specificity of 92%, PPV of 69% and NVP of 87% (the absolute number of patients with increase in troponin and relative icECG changes was not provided). Neither of those studies used a reference point, nor was the wire positioning before and after intervention described.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations