Intracavitary vaginal brachytherapy using a custom balloon applicator

Abstract: A custom balloon applicator was created to deliver intracavitary high‐dose‐rate brachytherapy to a patient with a superficial vaginal cancer. The patient was unable to be treated conventionally due to an extremely narrow introitus that prevented the introduction of a conventional cylinder applicator. The custom applicator was constructed by inserting a straight titanium tandem applicator through the drainage lumen of a Foley catheter. The applicator was inserted and the catheter balloon was inflated when posit… Show more