Intracardiac Electrode Detection of Early or Subendocardial Ischemia*

Abstract: Subendocardial and early transmural ischemia may have significant clinical consequences while manifesting few ECG changes. Catheters were designed to be introduced transvenously into the right ventricle (RV), and coronary sinus (CS) and transarterially into the left ventricle (LV). The intracavitary electrodes were modified so that the electrodes would not contact the endocardium. In twenty-two dogs ninety-eight graded stenoses of the circumflex and left anterior descending coronary arteries were performed whi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
13
0

Year Published

2004
2004
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(15 citation statements)
references
References 35 publications
2
13
0
Order By: Relevance
“…Indeed, in Cases 1 and 4, the surface 12-lead ECG was insensitive to left circumflex coronary artery occlusion. This finding is consistent with prior demonstrations that the ICEG is more sensitive than surface ECG to balloon occlusion during angioplasty (13,14,(17)(18)(19). Further, the real-time quantification available from a selfnormative implanted monitor increases sensitivity compared with that of traditional ECG.…”
Section: Discussionsupporting
confidence: 92%
“…Indeed, in Cases 1 and 4, the surface 12-lead ECG was insensitive to left circumflex coronary artery occlusion. This finding is consistent with prior demonstrations that the ICEG is more sensitive than surface ECG to balloon occlusion during angioplasty (13,14,(17)(18)(19). Further, the real-time quantification available from a selfnormative implanted monitor increases sensitivity compared with that of traditional ECG.…”
Section: Discussionsupporting
confidence: 92%
“…The rapid evolution of ICEG-detected ST-segment elevation in the current study is consistent with the clinical observations using a temporary right ventricular pacemaker lead during PCI, as reported by Varriale and Niznik (17), Fischell et al (16), and others (19,21,22).…”
Section: Discussionsupporting
confidence: 92%
“…Previous testing of this concept in patients, using an intracardiac electrogram (ICEG) obtained from a skin electrode on the left upper chest to a temporary (pacemaker) electrode in the right ventricular apex has demonstrated consistent, rapidly evolving, and dramatic ST-segment shifts during balloon occlusion during percutaneous coronary intervention (PCI) in humans (16,17,21,22). Permanently implanted leads have the advantage of being free from ST-segment artifact, muscle noise, transthoracic damping, or concerns about electrode movement over the course of electrocardiogram (ECG) monitoring.…”
mentioning
confidence: 99%
“…[11][12][13] The key advantage of the IT 6-lead-ECG as described by us 7 and the working groups of Theres et al 9 and Ghuran et al 10 is the heart-surrounding position of the leads in the present ICD generation. Theres et al 9 used a similar study protocol in a smaller patient group and compared the IT-ECG only with the surface ECG leads I, II, and V2.…”
Section: Discussionmentioning
confidence: 99%