2012
DOI: 10.1055/s-0031-1281839
|View full text |Cite
|
Sign up to set email alerts
|

Intra- und interobserver Variabilität sonografischer Untersuchungen an Patella- und Achillessehnen

Abstract: Our results suggest that the measurement of AT- and PT-a.p. -diameters is a reliable parameter. In contrast, reproducibility of AT- and PT-m.l.-diameters is questionable. The study corroborates the presence of hypoechogenicity and neovascularisation in asymptomatic tendons.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 8 publications
(12 reference statements)
0
5
0
Order By: Relevance
“…Furthermore, measurement location of thickness parameters is assumed to be of high relevance when interpreting physiological tendon adaptation by thickness, especially during maturation. According to prior sonographic reliability studies thickness parameters were used at presented sites instead of width or CSA-measurements (Fredberg et al, 2008 ; Cassel et al, 2012 ). For ATs, a second measurement location (thickest part in midportion) was chosen to consider possible length changes due to maturation.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Furthermore, measurement location of thickness parameters is assumed to be of high relevance when interpreting physiological tendon adaptation by thickness, especially during maturation. According to prior sonographic reliability studies thickness parameters were used at presented sites instead of width or CSA-measurements (Fredberg et al, 2008 ; Cassel et al, 2012 ). For ATs, a second measurement location (thickest part in midportion) was chosen to consider possible length changes due to maturation.…”
Section: Discussionmentioning
confidence: 99%
“…PT examinations were carried out in a supine position with 30° knee flexion, controlled by use of a soft pad. As previously described, both ATs and PTs were longitudinally examined to determine tendon diameters at a reference point 2 cm proximal to the calcaneal insertion (AT 2 cm) and 2 cm distal the Patella (PT 2 cm), respectively (Cassel et al, 2012 , 2016 ). Tendon thickness was reported to be reliably measureable at these standardized locations (Schmidt et al, 2004 ; Fredberg et al, 2008 ).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Several studies of inter‐observer reliability, using different methods when evaluating the severity of sonographically visible pathology, have been published [4, 8, 12, 35]. To our knowledge though, only one investigation has evaluated the use of a 4‐grade scale—similar to the Öhberg score—for neovascularisation [35], while in that study, power Doppler (PD) instead of colour Doppler (CD) was used.…”
Section: Introductionmentioning
confidence: 99%