2020
DOI: 10.1089/lrb.2019.0060
|View full text |Cite
|
Sign up to set email alerts
|

Intra-Rater Reliability and Agreement of the Indurometer When Used to Assess Mid-Calf Tissue Compressibility Among People Affected by Moderate to Severe Lymphedema in Bangladesh and Ethiopia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2020
2020
2021
2021

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 17 publications
0
5
0
Order By: Relevance
“…In the Myanmar cohort, a handheld tonometer, the Indurometer (Flinders and SA Biomedical Engineering, Australia), was able to detect a significant increase in mid-calf tissue compressibility among asymptomatic young people who were infected with LF, indicating that free fluid had begun to accumulate in the connective tissue spaces, even though there was no clinical sign of swelling. The Indurometer has demonstrated good intra-rater reliability in several populations including people affected by lower-limb lymphedema in this study [21,[23][24][25].…”
Section: Introductionmentioning
confidence: 60%
See 1 more Smart Citation
“…In the Myanmar cohort, a handheld tonometer, the Indurometer (Flinders and SA Biomedical Engineering, Australia), was able to detect a significant increase in mid-calf tissue compressibility among asymptomatic young people who were infected with LF, indicating that free fluid had begun to accumulate in the connective tissue spaces, even though there was no clinical sign of swelling. The Indurometer has demonstrated good intra-rater reliability in several populations including people affected by lower-limb lymphedema in this study [21,[23][24][25].…”
Section: Introductionmentioning
confidence: 60%
“…Tissue compressibility was quantified using the Indurometer (BME-1563; Flinders and SA Biomedical Engineering, Bedford Park, Australia) and the protocol was published in an intra-rater reliability analysis on the study population [23]. Briefly, the Indurometer is a handheld, battery-operated unit with a 1-centimeter (cm) diameter indenter projecting through a 7-cm diameter Perspex ® reference plate.…”
Section: Outcomes Measures and Data Collectionmentioning
confidence: 99%
“…Detailed data collection methods have been published [ 21 , 28 , 34 ]. The primary outcome was change in lymphedema status as determined by a combination of; (1) lymphedema stage [ 33 ], (2) mid-calf circumference, and (3) mid-calf tissue compressibility quantified by tissue tonometry using the Indurometer [ 35 ].…”
Section: Methodsmentioning
confidence: 99%
“…The Indurometer (BME-1563; Flinders and SA Biomedical Engineering, Bedford Park, South Australia) was used to quantify tissue compressibility at the same mid-calf point. A detailed description of the Indurometer and its operation were published in an intra-rater reliability analysis on the study population [ 34 ].…”
Section: Methodsmentioning
confidence: 99%
“…Tissue tonometry has been used in research on other forms of lymphoedema to quantify changes in skin stiffness and tissue compressibility. Good intra-rater reliability at all stages of filarial lymphoedema [ 15 ] including subclinical tissue change has been reported [ 9 ], but it is not widely available or accessible to local health staff. More recently, a portable three-dimensional infrared imaging tool has provided an innovative way to estimate limb volume measurements in a field setting [ 16 , 17 ].…”
Section: Introductionmentioning
confidence: 99%