2019
DOI: 10.1080/17434440.2019.1696675
|View full text |Cite
|
Sign up to set email alerts
|

Intra-rater and inter-rater reliability of cervical active range of movement in young asymptomatic adults using inertial sensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

3
12
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(23 citation statements)
references
References 50 publications
3
12
0
Order By: Relevance
“…According to the current evidence, four studies have analyzed the reliability of inertial sensors to assess CROM (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]). All of them assessed inter-rater reliability (Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]), two of them intra-rater reliability, (Schiefer et al, 2015[ 27 ]; Anoro-Hervera et al, 2019[ 3 ]), and two the validity of the inertial sensors (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]). In this context, the inter-rater reliability results presented by the Werium inertial sensor in the present study (ICC > 0.75) are very similar to those presented by the inertial sensors of the four previous studies (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…According to the current evidence, four studies have analyzed the reliability of inertial sensors to assess CROM (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]). All of them assessed inter-rater reliability (Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]), two of them intra-rater reliability, (Schiefer et al, 2015[ 27 ]; Anoro-Hervera et al, 2019[ 3 ]), and two the validity of the inertial sensors (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]). In this context, the inter-rater reliability results presented by the Werium inertial sensor in the present study (ICC > 0.75) are very similar to those presented by the inertial sensors of the four previous studies (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]).…”
Section: Discussionmentioning
confidence: 99%
“…All of them assessed inter-rater reliability (Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]), two of them intra-rater reliability, (Schiefer et al, 2015[ 27 ]; Anoro-Hervera et al, 2019[ 3 ]), and two the validity of the inertial sensors (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]). In this context, the inter-rater reliability results presented by the Werium inertial sensor in the present study (ICC > 0.75) are very similar to those presented by the inertial sensors of the four previous studies (Schiefer et al, 2015[ 27 ]; Raya et al, 2018[ 25 ]; Anoro-Hervera et al, 2019[ 3 ]; Gobbo et al, 2020[ 14 ]). However, only one of these analyzed the MDC 90 and SEM, contributing more data to clinical practice (Anoro-Hervera et al, 2019[ 3 ]).…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations