Intra-operative quality assessment of coronary artery bypass grafts

Abstract: Early coronary artery bypass graft (CABG) failure is a troubling complication that may result in a wide range of problems, including refractory angina, myocardial infarction, low cardiac output, arrhythmia, and fatal heart failure. Early graft failures are related to poor quality and size of the distal native vascular bed, coagulation abnormalities, or technical problems involving the graft conduits and anastomoses. Unfortunately, graft failure is difficult to detect during surgery by visual assessment, palpat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
15
0

Year Published

2006
2006
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(16 citation statements)
references
References 22 publications
1
15
0
Order By: Relevance
“…No papers regarding a TTFM flow phantom designed with silicone tubes in the measurement regions were found. Water has been the most cited fluid (Bednarik and May, 1995;Drost, 1978;Gordon, 1995), except for cases in which salt solutions were employed in ex vivo veins and arteries (Amaral and Michelini, 1997;Beldi et al, 2000;Groom et al, 2001;Lundell et al, 1993). The use of hydrostatic pressure for pressurization was found in the Transonic System calibration manual (Transonic…, 2009).…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…No papers regarding a TTFM flow phantom designed with silicone tubes in the measurement regions were found. Water has been the most cited fluid (Bednarik and May, 1995;Drost, 1978;Gordon, 1995), except for cases in which salt solutions were employed in ex vivo veins and arteries (Amaral and Michelini, 1997;Beldi et al, 2000;Groom et al, 2001;Lundell et al, 1993). The use of hydrostatic pressure for pressurization was found in the Transonic System calibration manual (Transonic…, 2009).…”
Section: Discussionmentioning
confidence: 99%
“…Among the TTFM calibration phantoms found in the literature, some use hydrostatic pressurization (Gordon, 1995;Transonic…, 2009) while others employ peristaltic pumps (Beldi et al, 2000;Groom et al, 2001). The materials employed in the measurement region ranged from synthetic materials, such as latex (Drost, 1978;Transonic…, 2009) and dialysis tubing (Bednarik and May, 1995;Gordon, 1995), to biological materials, such as saphenous human vein grafts (Beldi et al, 2000;Groom et al, 2001), carotid arteries of rats (Amaral and Michelini, 1997), sheep (Lundell et al, 1993) and pigs (Beldi et al, 2000).…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations