2022
DOI: 10.1016/j.pacs.2022.100346
|View full text |Cite
|
Sign up to set email alerts
|

Intra-instrument channel workable, optical-resolution photoacoustic and ultrasonic mini-probe system for gastrointestinal endoscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
38
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 23 publications
(38 citation statements)
references
References 56 publications
(203 reference statements)
0
38
0
Order By: Relevance
“…In the case of photoacoustic endoscopy (PAE) or intravascular photoacoustic (IVPA) imaging applications [ 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 ], related issues appear more frequently and seriously because it is a common hardware situation that the US transducer for signal detection and the associated preamplifier for the amplification of the detected signal are placed separately, with one at the distal end of the flexible probe section and the other with the proximal driving unit, at a distance of more than ~1.5 m, as the space allowed for installing a preamplifier circuit at the distal scanning tip is very limited. Moreover, due to the same limited space problem, it is not easy to apply proper shielding material to the connection path (i.e., the flexible probe section), which is located between the two parts mentioned [ 7 ].…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…In the case of photoacoustic endoscopy (PAE) or intravascular photoacoustic (IVPA) imaging applications [ 18 , 19 , 20 , 21 , 22 , 23 , 24 , 25 , 26 , 27 , 28 , 29 ], related issues appear more frequently and seriously because it is a common hardware situation that the US transducer for signal detection and the associated preamplifier for the amplification of the detected signal are placed separately, with one at the distal end of the flexible probe section and the other with the proximal driving unit, at a distance of more than ~1.5 m, as the space allowed for installing a preamplifier circuit at the distal scanning tip is very limited. Moreover, due to the same limited space problem, it is not easy to apply proper shielding material to the connection path (i.e., the flexible probe section), which is located between the two parts mentioned [ 7 ].…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, due to the same limited space problem, it is not easy to apply proper shielding material to the connection path (i.e., the flexible probe section), which is located between the two parts mentioned [ 7 ]. Consequently, it has been recognized that it is very difficult to implement a perfect hardware setup in PAE or IVPA that is not affected by interference noise at all, especially where the system is embodied at a laboratory level, and the problem related to the involvement of noise has been mentioned frequently in many reports [ 19 , 20 , 21 , 23 , 25 , 29 ].…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations